DOI QR코드

DOI QR Code

Alternately Zero Voltage Switched Forward, Flyback Multi-Resonant Converter Controller

교번으로 영전압 스위칭 되는 포워드, 플라이백 다중공진형 컨버터의 제어기

  • Published : 2002.09.01

Abstract

In the resonant converters which can provide high efficiency and high power density, the resonant voltage stress is about 4-5 times the input voltage. It needs the power switch with high ratings. This is a reason why the conduction loss is increased. In this paper, it proposes the alternately zero voltage switched forward, flyback multi resonant converter topology for reducing the voltage stress using alternately zero voltage switching technique. And the proposed AT forward MRC is experimentally considered about the loop gain with HP4194A network analyzer.

고효율 고전력 밀도를 제공하는 공진형 컨버터에 있어서 스위치에 걸리는 전압 스트레스는 입력전압의 4∼5배 정도여서, 높은 정격의 소자를 필요로 하기 때문에 전도손실을 증가시킨다. 본 논문에서는 이러한 문제점을 해결하기 위해 제안했던 교번으로 동작하는 포워드 다중공진형 컨버터에 적용한 회로 형태를 다른 컨버터에 적용한 예를 제시하였다. 그리고 제안한 AT포워드 다중공진형 컨버터의 루프 이득 특성을 알아보기 위해 HP4194A 네트워크 해석기를 이용해 실험적으로 측정한 결과에 대해 고찰하였다.

Keywords

References

  1. W. A. Tabisz, F. C. Lee, "Zero voltage switching multi-resonant technique-A novel approach to improved performance of high frequency quasi-resonant converters," IEEE PESC, pp.9-17,1988. https://doi.org/10.1109/PESC.1988.18109
  2. H. J. Kim, C. S. Kim, S. H. Lee, I. H. Lee., "A development of the 2MHz clamp mode forward ZVS MRC on board power module for telecommunication application," IEEE INTELEC, pp321-325, 1993.9. https://doi.org/10.1109/INTLEC.1993.388503
  3. C. S. Kim, "The operational characteristics of the AT Forward Multi-Resonant Converter," KIIEE, pp114-123, Vol.12, No.3, August 1998.
  4. C. S. Kim, "AT forward multi resonant converter modeling analysis," KIIEE, pp6-14, Vol.14, No.3, May 2000.
  5. H. J. Kim, C. S. Kim, "Phase shift controlled Forward multi resonant converter," KIEE Vol.44, No.8, pp1027-1035, 1995.8
  6. Richard Farrington, Milan M. Jovanovic, Fred C. Lee, "Constant frequency zero voltage switched multi resonant converters: analysis, design and experimental results," IEEE PESC, pp197-205, 1990. https://doi.org/10.1109/PESC.1990.131189