Response Function of Temperature Fluctuation in the Poiseulle Flows

포와셀 관유동에서 온도변화의 응답특성

  • Published : 2002.09.01

Abstract

The present study discusses the deviation from the pure dead-time model of passive scalars such as temperature and concentration in the Poiseulle flow Even in the case of no thermal diffusion, there exists a substantial amount of damping and large deviation of phase lag from that computed by the traditional dead-time model after only 10 diameter downstream. These are caused by the phase difference of temperature in the radial direction due to the nonuniform velocity distribution. In the presence of thermal diffusion, damping is more pronounced.

Keywords

References

  1. Process Control Systems(4th ed.) Shinskey, F.G.
  2. Process Control Marlin, T.E.
  3. Chemical Process Control An Introduction to Theory and Practice Stephanopoulos, G.
  4. Methods of Mathematical Physics v.2 Courant, R.;Hilbert, D.
  5. J. Computational Physics v.103 no.1 Compact Finite Difference Schemes with Spectral-like Resolution Lele, S.K. https://doi.org/10.1016/0021-9991(92)90324-R
  6. The Mathematica Book Wolfram, S.
  7. IMSL MATH/LIBRARY User's Manual(Version 2.0) IMSL