A methods of minimizing the measurement error brought from gas compositions was proposed by Hot wire Anemometer which don't have measurement resistance to calculate of gas vent in sanitary landfill. It was determined measurement error to compared velocity at the center of pipe to calculate using rotor meter and density gas compositions with velocity at the center of pipe to calculate using water head indicator which don't have measurement resistance. Considering the methods of minimizing gas velocity in sanitary landfill using hot wire anemometer and rotor meter, it was found to minimize within 10% as error of gas vent in sanitary landfill.

본 연구 목적은 계측저항이 없는 열선유속계를 이용하여 매립지 가스의 유량을 산정할 때 가스조성에 의해 발생되는 계측오차를 최소화할 수 있는 방안을 제시하고자하였다. Rotor meter와 가스조성 밀도를 이용하여 산정한 관 중심유속을 계측저항이 없는 열선유속계를 이용하여 구한 관 중심유속을 비교함으로서 계측오차를 측정하였다. 실험결과 열선 유속계와 rotor meter를 이용한 매립지 가스유속 계측오차의 최소화 방안을 통하여 매립지 가스유량의 오차 범위를 10% 이내로 최소화 할 수 있는 것으로 조사되었다.

Keywords

References

  1. 新版*化學機械の理論 と計算 龜井三郞
  2. philosophical Transactions of the Royal Society of London no.214 Louis Vessor King
  3. Louis Vessor King : philosophical Transactions of the Royal Society of London, 214, 373-432, 1914.