Analysis for the Flow and Wall Shear Stress with the Diameter Ratios of an Abdominal Aortic Aneurysm in a Pulsatile Flow

맥동 유동에서 복부 대동맥류의 직경비에 따른 유동 및 벽면전단응력 해석

  • 모정하 (원광대학교 공과대학 기계·시스템디자인공학부)
  • Published : 2002.06.01

Abstract

The objective of the present study was to two-dimensionally investigate the characteristics of flow and wall shear stress under pulsatile flow in the aneurysm which is a local dilatation of the blood vessel for pulsatile flow. The numerical simulation using the commercial software were carried out for the diameter ratios(ratio of maximum diameter of aneurysm to the diameter of blood vessel) ranging from 1.5 to 2.5 and Womersley number, 15.47. It was shown that a recirculating flow at the bulge was developed and disappeared for one Period and the strength of vortex increased with the diameter ratio Especially. at time of 3.19s. the very weak recirculating flow was developed at the left upper sites of the aneurysm. The maximum values of the wall shear stress increased in Proportion to the diameter ratio. However. the Position of a maximum wall shear stress was the distal end of the aneurysm(z = 35mm) regardless of the diameter ratios.

일정한 주기를 갖는 맥동유동에 대하여 혈관이 확장될 때 나타나는 동맥류 내부에서의 유동 및 벽면전단응력의 특성을 2차원적으로 고찰하였다. 상용 소프트웨어를 이용하여 직경비 1.5. 2.0 및 2.5 그리고 Womersley 수 15.47에 대한 복부대동맥내의 유동 현상을 수치해석하였다. 해석결과 동맥류 상단부에서 형성된 재순환유동은 시간의 흐름에 따라 생성과 소멸을 반복하였고. 시간이 3.19초인 경우, 동맥류 입구부 상단 근처에서 매우 미약한 재순환유동이 발달하고 있음을 예상할 수 있었다. 그리고 직경비가 증가할수록 동맥류 말단부에서 전단응력의 변화의 폭이 증가하였고 최대 전단응력의 값도 증가하는 것을 알 수 있었다. 그러나 최대 벽면전단응력의 발생 위치는 직경비의 변화와 거의 무관하였으며 동맥류 말단부 근처 (z : 35mm)에서 발생하였다

Keywords

References

  1. J.of Biomechanical Eng. v.115 Steady Flow in Abdominal Aortic Aneurysm Models R.D. Budwig;D.Elger;H.Hooper;J.Slippy https://doi.org/10.1115/1.2895506
  2. Invest.Ratiol v.27 A Qualitatibe Investigation of Turbulence in the flow Through a Model of an Abdominal Aortic Aneurysm T.Schrader;R.A.Peattie;E.I.Bluth;C.E.Comstock https://doi.org/10.1097/00004424-199207000-00008
  3. J.of Ultrasound Med. v.13 Decelopment of Turbulent in Steady Flow Through Medels of Abdominal Aortic Aneurysms R.A.Peattie;T.Schrader;E.I.Bluth;C.E.Comstock
  4. Annals of Biomedical Eng. v.23 Experimental Investigation of Steady Flow in Rigid Models of Abdominal Aortic Aneurysms C.L.Asbury;J.W.Ruberti;E.I.Bluth;R.A.Peattie https://doi.org/10.1007/BF02368298
  5. J.of Biomechanical Eng. v.118 Steady Flow in an Aneurysm Model: Correlation Between Fluid Dynamics and Blood Platelet Deposition D.Bluestein;L.Niu;R.T.Schoephoerster;M.K.Dewanjee https://doi.org/10.1115/1.2796008
  6. Int.J.of Heat and Fluid Flow v.21 Steady and Pulsatile Flow Studies in Abdominal Aortic Aneurysm Models Using Particle Imang Velocimetry Yu,S.C.M. https://doi.org/10.1016/S0142-727X(99)00058-2
  7. J.of Biomed.Eng.Res. v.21 no.2 A Study on the Measurement of Wall Shear Rate in the Abdominal Aortic Aneurysm S.E.Oh;K.Rhee
  8. Proceedings of the DSME Spring Annual Conference(E) Analysis for the Flow and Wall Shear Stress with a Dilatation of an Abdominal Aortic Aneurysm S.C.Shin;K.W.Kim;G,H,Lee;J.H.Moh;D.H.Kim
  9. ASME J.of Biomechanical Emg. v.119 Wall Shear Stress Distribution in an Abdominal Aortic Bifuraction Model: Efects of Vessel Compliance and Phase Angle Between Pressure and Flow Waveforms C,S,Lee;J.M.Tarbell https://doi.org/10.1115/1.2796098
  10. Critical Reciews in Biomedical Engineering v.19 Bilflutd dynamics of arterial Bifurcations S.Lou;W.J.Yang
  11. FLUENT User's Guide Volume