Measurement of the Shape in the Radioactive Area by Ultrasonic Wave Sensor

  • Park, Koon-Nam (HANARO Application Research, Korea Atomic Energy Research Institute) ;
  • Sim, Chuel-Muu (HANARO Application Research, Korea Atomic Energy Research Institute) ;
  • Park, Chang-Oong (HANARO Application Research, Korea Atomic Energy Research Institute) ;
  • Lee, Chang-Hee (HANARO Application Research, Korea Atomic Energy Research Institute) ;
  • Park, Jong-Hark (Department of Mechanical Design Engineering, Chungnam National University)
  • 발행 : 2002.07.01

초록

The HANARO ( High-flux Advanced Neutron Application Reactor) has been operated since 1995. The Cold Neutron (CN) hole was implanted in the reflector tank from the design stage. Before a vacuum chamber and a moderator cell for the cold neutron source are installed into the CN hole, it is necessary to measure exactly the size of the inside diameter and thickness of the CN hole to prevent the interference problem. Due to inaccessibility and high radiation field in the CN hole, a mechanical measurement method is not permitted. The immersed ultrasonic technique is considered as the best way to measure the thickness and the diameter of the CN hole. The 4-Axis manipulator was designed and fabricated for locating the ultrasonic sensors. The transducer of an ultrasonic sensor having 10 MHz frequency leads to high resolution as much as 0.03mm. The inside diameter and thickness of 550 points of the CN hole were measured using 2 channel ultrasonic sensors. The results show that the thickness and inside diameter of the CN hole is in the range of 3.3∼6.7mm and 156∼ 165mm, respectively. This data will be a good reference for the design of the cold neutron source facility.

키워드

참고문헌

  1. Albert S. Birks, Robert E. Green Jr, Paul Mclntire, 1991, 'Nondestructive Testing Handbook' Vol. 7 Ultrasonic Testing, American Society for Non-destructive Testing, p. 198, p. 259, pp. 269-373
  2. Chang Oong Choi, Man Soon Cho, Kook Nam Park, Jae Min Sohn, Chuel Muu Sim, Young Hyun Choi, Muu Oung Lee, 1999, 'Development of Cold Neutron Source,' KAERI/RR-1916/98, pp. 117-215
  3. Kook Nam Park, Chuel Muu Sim, Chang Oong Choi, 2000, 'Measurement of Shape of the Cold Neutron Source Vertical Hole by Ultrasonic Wave Sensor,' Journal of the Korean Society of Mechanical Engineering Vol. A-24, No. 9, pp. 2167-2173
  4. Kook Nam Park, Jong Hark Park, Man Soon Cho, Chang Oong Choi, Seong Yoon Yoo, 1999, 'A Study on Cooling of the CNS Moderator in HANARO,' The Korea Institute of Applied Superconductivity and Cryogenics 1st Conference '99, pp. 177-181
  5. Kook Nam Park, Chuel Muu Sim, Young Hyun Choi, Kil Mo Koo, Yoong Sup Lee, Chang Oong Choi, 1999, 'Measurement of Shape by Ultrasonic Waves and Surface Inspection of the Cold Neutron Source Vertical Hole,' KAERI/TR-1261/99
  6. Kyung Woo Kwan, Hyung Mo Kwang, 'A Measuring Technology,' Youngji Munhwasa, p. 73, pp. 158-165
  7. Man Soon Cho, Kook Nam Park, Byung Chuel Lee, Jae Min Sohn, Sang Jun Park, Chuel Muu Sim, Chang Oong Choi, 1999, 'Heat Load Measurement in the Vertical Hole for Installation of Hanaro CNS,' Proceeding of The 6th Asian Symposium on Research Reactor, JAERI-Conf 99-006, pp. 385-391
  8. Stefan Kocis, Zdenko Figura, 1996, 'Ultrasonic Measurements and Technologies,' Chapman & Hall, pp. 15-16