The microbiological examinations of food service operations were conducted for the hygienic evaluation at four elementary schools in Busan, Korea. Total one hundred and seventy two swabbed samples using sponge were collected from the surface of environments, utensils and equipments of food service facilities and analyzed by measuring the total, coliform and psychrotrophic count. Sampling sites were the surfaces of floors, drains, walls, knives, cutting boards, rubber gloves, vinyl aprons, plastic containers, carriers, shelves, trays, dry shelves, electric tray dryer, food containers, soup containers, rice cookers, frying pans, boiling cookers, refrigerators, dumb waiters and dishwashers. The swabbed samples kept in an ice-parked box were transported to a laboratory and analyzed. The results demonstrated that the degree of contamination depended on the sampling sites. Averages of total counts of surface swab samples were ranged from 0.62 to 7.79 Log CFU/200 cm$^2$. The level of coliforms were ranged from not detectable to 5.26 Log CFU/200 cm$^2$, and those of psychrotrophs from not detectable to 6.15 Log CFU/200 cm$^2$. The severely contaminated sites were dumb waiters, drains, rice cookers, knives, plastic containers and floors. Also cutting boards, rubber gloves, carriers, drying shelves, vinyl aprons, boiling cookers, soup containers, frying pans and refrigerators were highly contaminated with the level of abode 3.5 Log CFU/200 cm$^2$. Therefore, those sites should be focused and controlled according to control points of sanitation standard operating procedures (SSOP). Also, periodic microbiological examination in addition to visual examination is recommended on these highly contaminated sites indicated above results at food service operations in elementary school.

부산시내 초등학교 4곳을 방문하여 급식소 환경 , 기계, 기구에 대해 HACCP 적용시 중점관리점을 파악하기 위하여 위생평가를 실시하였다. 환경에 대한 위해 요소분석 결과 위해도가 높은 지역과 낮은 지역이 확실히 드러났으며 위생에 특별한 주의를 기울여야 할 장소가 확인되었다. 위생평가시 조사한 21곳의 시료장소 중에서 급식소의 바닥과 스테인레스 스틸제재로 된 배수설비 표면에서 높은 수의 세균과 대장균 군이 관찰되었다. 또한 덤웨이터에서 가장 높은 수의 세균과 대장균군이 발견되었고 밥통, 칼, 도마, 고무장갑, 운반대, 비닐앞치마, 플라스틱 소쿠리, 프라이 팬, 냉장고내부에서도 높은 수의 미생물이 검출되었으며 특히 기구들을 건조시키는 공기건조대에서도 오염도가 심해 특별히 관리 해야되는 부분으로 확인되었다. 또한 급식소의 내부에서 사용되는 물건 중 스테인레스 스틸로 만들어진 운반대, 선반, 식판, 국통 등에서도 단위면적당 수천 마리의 미생물이 오염된 것으로 나타나 용기를 통한 식중독균의 오염이 우려되고 있다. 따라서 단체 급식소의 HACCP의 적용에 앞서 이들 장소에 대해 위생표준 관리기준(SSOP)에 의한 중점관리가 수행되어져야 하며 주기적인 미생물 검사를 실시하여 미생물의 오염상태를 점검해야 할 것이다. 또한 주방기구나 용기는 이물질을 먼저 제거하고 세척제를 사용하여 세척한 다음 소독제를 사용한 소독을 실시한 후 말려 재사용하는 방법 이 철저히 적용되어야 할 것이다.

Keywords

References

  1. 김평수. 2001. 생활교육으로서의 학교급식정착방안. 교육인적자원부 학교급식 수련회자료집. p 6-12.
  2. 곽동경, 정동관. 2000. 학교급식에 효율적인 HACCP 적용방안 및 환경위생확보 신속검사시스템 개발. 제16차 한국식품위생안전성 학회 학술발표지. p 103-111.
  3. 곽동경, 김정리, 남순란. 1993. 공동조리급식체계를 활용한 학교급식의 발전방향 모색연구. 1993년도 대한영양사회 학교분과 연차대회자료집. p 67-75.
  4. 교육부. 2001. 최근 3년간 식중독발생률 분석자료('98-2000).
  5. 식품의약품안전청. 2001. 식중독예방대책.
  6. Kassa H, Harrington B, Bisesi M, Khuder S. 2001. Comparisons of microbiological evaluations of selected kitchen areas with visual inspections for preventing potential risk of foodborne outbreaks in food service operations. J Food Protection 64: 509-513. https://doi.org/10.4315/0362-028X-64.4.509
  7. Tebbutt GM. 1991. Development of standardized inspection in restaurants using assessments and microbiological sampling to quantify the risks. Epidemiol Infect 107: 393-394. https://doi.org/10.1017/S0950268800049037
  8. Tebbutt GM, Southwell JM. 1989. Comparative study of visual inspections and microbiological sampling in premises manufacturing and selling hish-risk foods. Epidemiol Infect 103: 475-489. https://doi.org/10.1017/S0950268800030880
  9. Olsen SJ, MacKinson LC, Goulding JS, Bean NH, Slusker L. 2000. Surveillance for foodborne disease outbreak-United States, 1993-1997. Morbid Mortal Weekly Rep 49: 1-51.
  10. Buckalew JJ, Schaffner DW, Solberg M. 1996. Surface sanitation and microbiological food quality of a university foodservice operation. J Foodservice Systems 9: 25-39.
  11. Stevenson K, Bernard DT. 1995. HACCP: Establishing hazard analysis critical control point programs. National Food Processors Association.
  12. 신광순. 1998. HACCP 이론과 실천모델. 한국 HACCP 연구회.
  13. Food and Drug Administration. 1992. Bacteriological analytical manual. 7th ed. AOAC International, Arlington.
  14. American Public Health Association. 1992. Compendium of methods for the microbiological examination of food. 3rd ed. American Public Health Association.
  15. Harrigan WF, McCance ME. 1976. The examination of food processing plant. In Laboratory methods in food and dairy microbiology. Academic Press. London. p 231-236.
  16. Chun HJ, Paik JE, Lee YK, Kim ES. 1998. The microbiological assessment of plastic container and kitchen utensils used in employee feeding foodservice operation in Seoul. Korean J Soc Food Sci 14: 21-24.
  17. Solberg M, Buckalew JJ, Chen CM, Schaffner DW, O'Neill K, McDowell J, Post LS, Boderck M. 1990. Microbiological safety assurance system for foodservice facilities. Food Technol 44: 68-73.
  18. US Food and Drug Administration. 1997. Food Code, 4-7 Sanitation of equipment and utensils, Public Health Service and Food and Drug Administration.

Cited by

  1. Importance-Performance Analysis about Sanitation Management Items at General Hospital Foodservice Operations vol.29, pp.1, 2013, https://doi.org/10.9724/kfcs.2013.29.1.63
  2. The Microbiological Assessment and Identification of Food Utensils and Food Service Facilities in School vol.29, pp.3, 2014, https://doi.org/10.13103/JFHS.2014.29.3.189
  3. Inhibition Effect of Sanitizers against E. coli and a Hygienic Condition on the Surface of Utensils and Equipments Used to Food Service vol.31, pp.6, 2002, https://doi.org/10.3746/jkfn.2002.31.6.965
  4. Evaluation and Reduction of Microbiological Hazard of Spoon and Spoon Case Carried by Nursery School Children vol.40, pp.1, 2011, https://doi.org/10.3746/jkfn.2011.40.1.116
  5. Usage Status Survey on Some Essential Facilities, Equipment and Documentary Records for HACCP Implementation in Contract Foodservices vol.33, pp.7, 2004, https://doi.org/10.3746/jkfn.2004.33.7.1162
  6. Effectiveness of a dry kitchen system on controlling the microbiological safety of food and contact surfaces vol.22, pp.4, 2013, https://doi.org/10.1007/s10068-013-0195-5
  7. A Microbiological Analysis and Hazard Factor Evaluation of Food Utensils and Fixtures of Food Service Operations in Schools vol.37, pp.5, 2011, https://doi.org/10.5668/JEHS.2011.37.5.376
  8. Antioxidant Activity of Hwangki and Beni-Koji Extracts and Mixture vol.40, pp.1, 2011, https://doi.org/10.3746/jkfn.2011.40.1.001
  9. Verification of the HACCP System in School Foodservice Operations - Focus on the Microbiological Quality of Foods in Non-Heating Process - vol.33, pp.7, 2004, https://doi.org/10.3746/jkfn.2004.33.7.1154
  10. 급식시설 . 설비 표면의 위생상태 및 계절별 미생물 균수의 변화 vol.33, pp.10, 2004, https://doi.org/10.3746/jkfn.2004.33.10.1653
  11. 한식당 설비와 기구의 미생물 평가 vol.34, pp.10, 2005, https://doi.org/10.3746/jkfn.2005.34.10.1611
  12. 병원급식소의 HACCP 제도 적용을 위한 미생물학적 위해도 분석 vol.35, pp.3, 2006, https://doi.org/10.3746/jkfn.2006.35.3.383
  13. 대학급식소 작업시설과 환경의 미생물 오염도 분석 및 작업환경 실태조사 vol.23, pp.2, 2002, https://doi.org/10.14373/jkda.2017.23.2.180
  14. Influence of the Smoking and Spitting Behaviors in Public Smoking Areas on the Microbial Contamination and Spread vol.43, pp.11, 2002, https://doi.org/10.4491/ksee.2021.43.11.679