Analysis of Insulation Aging Mechanism in Generator Stator Windings

발전기 고정자 권선의 절연열화 메카니즘 분석

  • 김희동 (한전 전력연구원 발전연구실)
  • Published : 2002.02.01

Abstract

The mica/epoxy composite used in generator(rated 22 kV and 500 MW) stator windings was aged at 180$\^{C}$ for up to 1000 hours in air and hydrogen. The degradation mechanism was investigated through the defect of evolution and microstructural analysis by performing SEM(Scanning Electron Microscope). As the thermal aging time increases, the number of voids per unit volume increases at the mica/epoxy interface of generator stator windings. The aged specimens in hydrogen showed retarded generation and growth of voids. Accelerated aging tests were conducted using the combination of thermal and electrical aging in air and hydrogen. The aging was carried out at a combined stress such as thermal aging at 110$\^{C}$, electrical aging at 5.5 kV/mm and frequencies 420 Hz in air, and electrical aging at 5.5 kV/mm and frequencies 420 Hz in hydrogen (pressure 4 kg/㎠). Thermal and electrical aging generates large voids at the mica/epoxy interface in air. Electrical aging in hydrogen also generates small voids, delaminations and cracks in mica tapes.

Keywords

References

  1. T. IEE Japan v.114-A no.12 Current method of insulation life expectancy for power apparatus K. Mreuger;S.Oulski;H. Krivda
  2. 전기전자재료학회논문지 v.14 no.1 절연파괴 예측을 위한 트리방전의 영상처리에 관한 연구 오무송;김태성
  3. 일본 전기학회 전기설비의 진단기술 川鳥國定
  4. IEEE Trans. on Dielectrics and Electrical Insulation v.2 no.3 The role of microscope defects in multistress aging of micaceous insulation K. Kimura;Y. Kaneda https://doi.org/10.1109/94.395419
  5. IEEE Trans. on Electrical In-sulation v.27 no.5 Assessment of deterioration in epoxy;mica machine insulation Y.J. Kim;J.K. Nelson https://doi.org/10.1109/14.256478
  6. Proceeding aging of high voltage stator bars Multistress aging of high voltage stator bars R.C. Sheehy;T.R. Blackburn;J. Rungis
  7. IEEE Trans. on Electrical Insulation v.EI-18 no.5 Insulation effects of hydrogen gas for cooling turbine-driven generator H. Mimura;E. Koyanagi;S. Kenjo https://doi.org/10.1109/TEI.1983.298640
  8. 일본전기학회기술보고 no.488 고체 절연재료의 계면효과 고체절연재료의계면효과조사전문위원회
  9. 전기전자재료학회논문지 v.10 no.4 발전기 고정자 권선에 사용되는 마이카/에폭시 복합재료의 기계적 특성에 관한 연구 김희동;김희곤;김태완;강도열
  10. 한국전기전자재료학회 1999춘계학술대회논문집 고압전동기 고정자 권선 절연재료의 미세구조 특성 김희동;주영호

Cited by

  1. Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings vol.9, pp.1, 2014, https://doi.org/10.5370/JEET.2014.9.1.280