Abstract
The plasma display panel with the electrode structure of new discharge AND gate was proposed and the driving system for experiment was developed. And discharge AND gate operation was verified. Discharge AND gate operated by the operation speed of 8${\mu}\textrm{s}$ and the operation margin of 20V. It was known to be able to control the discharge of the adjoining scan electrode accurately. Because this method uses the DC discharge, the control of the discharge can be facilitated compared with conventional discharge AND gate. Moreover, because the input discharge and the output discharge of AND gate are separate, the display discharge can be prevented from passing AND gate. Therefore it is possible to app1y to the large screen plasma display. And the decrease of contrast ratio does not occur because the scanning discharge does not influence the picture quality.
새로운 방전 AND gate를 가지는 플라즈마 디스플레이 패널이 제안되었고 이를 검증하기 위한 구동 회로 시스템이 개발되었다. 그리고 방전 AND gate의 동작이 검증되었다. 방전 AND gate는 8$\mu\textrm{s}$의 동작속도와 20V의 동작마진을 가지고 동작하였으며 인근 주사라인의 방전을 정확히 제어할 수 있다는 것을 알았다. 이 방식은 직류 방전을 사용함으로 종래의 방전 AND gate에 비해 손쉽게 방전을 제어할 수가 있다. 더구나 AND gate의 입력방전과 출력방전이 분리되어 동작하기 때문에 디스플레이 방전이 AND gate를 통과하는 것을 방지할 수 있다. 그러므로 대화면 플라즈마 디스플레이에의 적용이 가능하고 주사방전이 화질에 영향을 주지 않으므로 명암비의 저하가 일어나지 않는다.