Abstract
We have carried out a nondestructive close examination for the purpose of the structural safety diagnosis of the Dabo Pagoda of Bulkuk temple located in Kyungju, Kyungbuk Korea. For estimating the mechanical properties of each rock block of the pagoda, ultrasonic measurements were conducted at 641 points of 255 blocks. The P-wave velocity ranges from 584m/sec through 5,169m/sec, and averages 2,901m/sec Based on this result, the uniaxial compressive strength was estimated to be $93{\sim}1,943kg/cm^2\;with\;396kg/cm^2$ of average, and the index of weathering is $0.07{\sim}0.88$ with 0.43 of average, which means the moderate degree of weathering. The comparison of the rock strength of each block with the overburden acting on the block reveals that the rock blocks related to the structure of the pagoda are relatively sound for uniform stress, but it is highly possible for a concentrated stress to lead to a partial failure. We suggest a monitoring of cracks due to the concentrated stress. The parapets of 1st and 2nd floors composed of small rock pieces are severely weathered. However, this is not directly related to the structural safety of the pagoda.
경상북도 경주시에 위치한 불국사 다보탑의 구조 안전 진단을 목적으로 탑의 각 부재에 대한 비파괴 정밀 조사가 실시되었다. 암석 부재의 역학적 성질을 추정하기 위해 255개 부재에서 641 지점에서 초음파 속도를 측정하였으며, 그 결과는 P-파 속도 범위가 $584{\sim}5169m/sec$이며 평균 속도는 2876m/sec이다. 일축압축강도는 $93{\sim}1314kg/cm^2$ 범위로 평균치가 $396kg/cm^2$이고, 풍화도지수는 $0.07{\sim}0.88$의 범위로 평균 0.43으로 중간정도의 풍화를 받은 것으로 나타났다. 각 암석부재의 파괴강도와 이에 작용하는 응력을 비교한 결과, 탑의 구조에 관계된 부재들의 상태는 비교적 양호한 상태를 보여주지만, 편하중에 의한 부분 파괴의 가능성이 남아있다. 편하중에 의한 균열이 계속 진행중인지 모니터링이 필요하며, 편하중을 제거하기 위한 대책이 중요하다. 1층 및 2층 옥신부 주변의 난간은 비교적 작은 부재들로 이루어져 있어 풍화가 많이 진전되었지만 구조적 불안정에는 직접 관련이 없다.