The Solution of Severe Vibration Problen of the Secondary Cooling Pump in HANARO

하나로 2차 냉각펌프의 고진동 해소방안

  • Published : 2002.12.01

Abstract

The heat produced by the fission in the fuel of HANARO, 30 MW of research reactor, was transferred from the primary cooling water to the secondary cooling water through heat exchangers. The secondary cooling water absorbing the heat was circulated by secondary cooling pumps and cooled through 33 MW of cooling tower. Each capacity of the three secondary cooling pumps was fifty percent ($50\%$) of full load. The two pumps were normally operated and the other pump was standby. One of the secondary cooling pumps has often made troubles by high vibration. To release these troubles the pump shaft has been re-aligned, the pump bearing has been replaced with new one, the shaft sleeve has been replaced with new one, the shaft and the impeller have been re-balanced representatively and/or the vibration of motor has been tested by disconnecting the shaft of pump. But the high vibration of pump cannot be cleared. We find out the weight balance trouble of the assembly in which the impeller is installed in the shaft. After clearing the trouble, the high vibration is relieved and the pump is operated smoothly. In this paper, the trouble solution shooting method of secondary cooling pump is described including the reason of high vibration

Keywords

References

  1. 비안전성 펌프 및 체크 밸브점검 박용철
  2. 取扱 設明書 Handy Digital 振動計, Model 201
  3. Performance Test Procedure for Secondary Cooling Pump Kim, D. K.
  4. Instruction Manual for Secondary Cooling Pump Kim, D. K.
  5. Technical Specification for Secondary Cooling Pumps Kim, C. H.
  6. Korean Industrial Standard Balance Quality of Rotating Machinery, KS B 0612
  7. Couplings, CAT-61-No. 9405 Hwa Sung Korea Co., Ltd
  8. Hydraulic Institute Standards for Centrifugal, Rotary & Reciprocating Pumps (14th ed.) Hydraulic Institute