DOI QR코드

DOI QR Code

Determination of Boron Steel by Isotope-Dilution Inductively Coupled Plasma Mass Spectrometry after Matrix Separation


Abstract

The concentration of B in steels is important due to its influence on mechanical properties of steel such as hardenability, hot workability, and creep resistance. An analytical method has been developed to determine B in steel samples by high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). National Institute of Standard and Technology Standard Reference Material (NIST SRM) 348a was analyzed to validate the analytical method. The steel sample was digested in a centrifuge bottle with addition of aqua regia and $^{10}B$ spike isotope. Sample pH was then adjusted to higher than 10 to precipitate most matrix elements such as Fe, Cr, and Ni. After centrifugation, the supernatant solution was passed through a cation exchange column to enhance the matrix separation efficiency. B recovery efficiency was about 37%, while matrix removal efficiency was higher than 99.9% for major matrix elements. The isotope dilution method was used for quantification and the determined B concentration was in good agreement with the certified value.

Keywords

References

  1. Materials Handbook, 11th Ed.; McGraw-Hill: New York, USA, 1977; pp 102-103.
  2. Ambrose, A. D.; Harine, M.; Staats, G.; Weichert, E. Steel Res. 1989, 60, 363. https://doi.org/10.1002/srin.198901669
  3. Sah, R.; Brown, P. H. Microchemical Journal 1997, 56, 285. https://doi.org/10.1006/mchj.1997.1428
  4. Gregoire, D. C. J. Anal. At. Spectrom. 1990, 5, 623. https://doi.org/10.1039/ja9900500623
  5. Evans, S.; Krahenbuhl, U. J. Anal. At. Spectrom. 1994, 9, 1249. https://doi.org/10.1039/ja9940901249
  6. Coedo, A. G.; Dorado, T. ISIJ Int. 1994, 34, 997. https://doi.org/10.2355/isijinternational.34.997
  7. Coedo, A. G.; Dorado, T.; Fernandez, B. J.; Alguacil, F. J. Anal. Chem. 1996, 68, 991. https://doi.org/10.1021/ac9510292
  8. Aggarwal, J. K.; Palmer, M. R. Analyst 1995, 120, 1301. https://doi.org/10.1039/an9952001301
  9. Ishikawa, T.; Nakamura, E. Anal, Chem. 1990, 62, 2612. https://doi.org/10.1021/ac00222a017
  10. Tanner, S. D. Spectrochim. Acta 1992, 47B, 809.
  11. Al-Ammar, A.; Gupta, R. K.; Barnes, R. M. Spectrochimica Acta 1999, 54B, 1077.
  12. Vanderpool, R.; Hoff, D.; Johnson, P. E. Environ. Health Perspect 1994, 102, 13. https://doi.org/10.1289/ehp.94102s1013
  13. Sun, D.; Waters, J. K.; Mawhinney, T. P. J. Anal. At. Spectrom. 1997, 12, 675. https://doi.org/10.1039/a606283k
  14. Watters, R. L. The First Draft on the Isotope Dilution Mass Spectrometry Protocol for ICP-MS; National Institute of Standards and Technology: Gaithersburg, MD, USA, 1995.
  15. Park, C. J.; Cha, M. J.; Lee, D. S. Bull. Korean Chem. Soc. 2001, 22, 205.
  16. Park, C. J. Analyst 1996, 121, 1311. https://doi.org/10.1039/an9962101311
  17. Catterick, T.; Fairman, B.; Harrington, C. J. Anal. At. Spectrom. 1998, 13, 1009. https://doi.org/10.1039/a801233d

Cited by

  1. Determination of boron in high-temperature alloy steel using non-linear inter-element correction and microwave plasma-atomic emission spectrometry vol.28, pp.8, 2013, https://doi.org/10.1039/c3ja50103e
  2. Matrix effects during laser ablation MC ICP-MS analysis of boron isotopes in tourmaline vol.29, pp.5, 2014, https://doi.org/10.1039/c3ja50241d
  3. Development and application of an analyte/matrix separation procedure for multi-element trace analysis of steel alloys by means of sector-field ICP-mass spectrometry vol.29, pp.6, 2014, https://doi.org/10.1039/C4JA00073K
  4. Current literature in mass spectrometry vol.38, pp.7, 2003, https://doi.org/10.1002/jms.410
  5. Non-destructive quantification of total boron and its isotopic composition in boron based refractory materials by PIGE and an inter-comparison study using TIMS and titrimetry vol.33, pp.5, 2018, https://doi.org/10.1039/C7JA00416H
  6. Determination of ultratrace boron concentrations in uranium oxide by isotope dilution-thermal ionization mass spectrometry using a simplified separation procedure vol.169, pp.3-4, 2010, https://doi.org/10.1007/s00604-010-0345-x
  7. Determination of Bi Impurity in Lead Stock Standard Solutions by Hydride-generation Inductively Coupled Plasma Mass Spectrometry vol.25, pp.2, 2002, https://doi.org/10.5012/bkcs.2004.25.2.233
  8. Quasi-non-destructive isotopic ratio measurement of boron in irradiated control rod B4C pellets using a home-built reflectron time-of-flight mass spectrometer vol.309, pp.None, 2002, https://doi.org/10.1016/j.ijms.2011.09.012
  9. 질산-이플루오린화암모늄 분해 및 ICP-MS에 의한 철강 중 붕소 정량에 관한 연구 vol.27, pp.6, 2014, https://doi.org/10.5806/ast.2014.27.6.352