Biomechanical changes in lower quadrant after manipulation of low back pain patients with sacroiliac joint dysfunction

요통환자의 엉치엉덩관절 기능부전에 대한 도수교정 후에 하지의 생체역학적인 변화

  • Oh, Seung-Gil (Dept. of Physical Therapy, Seoul Health College) ;
  • Yoo, Seung-Hee (Depart. of Physical Education, Graduate School of Kyung Hee University)
  • 오승길 (서울보건대학 물리치료과) ;
  • 유승희 (경희대학교 대학원 체육학과)
  • Published : 2001.03.31

Abstract

The purposes of this study were to compare pelvic tilt. range of motion(ROM) of hip rotation, and leg length difference before and after manipulation and to investigate correlation between changes of each variables after manipulation of sacroiliac pint in 31 low back pain patients(11 males, 20 females) with sacroiliac pint dysfunction. The sacroiliac pint of patients was manipulated on the side of anterior pelvic tilt, using the technique described by Stoddard(1962) and Greenmann (1996). I used this technique because it usually eliminated sacroiliac Pint dysfunction in one treatment session. SPSS for window computer system was used to analyze the data. Also t-test was performed for comparison of the variables before and after manipulation, and Pearson product-moment correlation analysis and regression analysis were performed for changes of each variables after manipulation. The result were as follows: 1. The pelvic tilt after manipulation was significantly decreased(mean=$2.79^{\circ}$) compared with the pelvic tilt before manipulation(p=.001). 2. The PROM of hip internal rotation ipsilateral to anterior pelvic tilt after manipulation significantly decreased (mean = $1.88^{\circ}$) compared with hip internal rotation before manipulation (p=.008). The PROM of hip internal rotation ipsilateral to posterior pelvic tilt after manipulation significantly increased(mean = $1.29^{\circ}$) compared with hip internal rotation before manipulation (p=.029). 3. The PROM of hip external rotation ipsilateral to anterior pelvic tilt after manipulation significantly increased(mean=$2.42^{\circ}$) compared with the hip external rotation before manipulation(p=$2.42^{\circ}$) compared with the hip external rotation ipsilateral to posterior pelvic tilt after manipulation significantly decreased(mean = $1.84^{\circ}$) compared with the hip external rotation before manipulation (p=.008). 4. Leg length difference after manipulation significantly decreased(mean=2.15 mm) compared with leg length difference before manipulation (p=.008). Regression analysis revealed that a fair correlation was found between change in leg length difference and change in anterior pelvic tilt after manipulation(p=.009). 5. Pearson product-moment correlation coefficient was used to assess differences of the variables after manipulation. A fair correlation was found between change in leg length difference and change in anterior pelvic tilt after manipulation(r=.462, p<.01). A fair correlation was found between change in anterior pelvic tilt and change in hip internal rotation ipsilateral to anterior pelvic tilt(r=.397, p<.05) and between change in anterior pelvic tilt and change in hip external rotation ipsilateral to anterior pelvic tilt(r=.516, p<.01). A fair correlation was found between change in posterior pelvic tilt and changes in hip internal rotation ipsilateral to posterior pelvic tilt (r=.441, p<.05) and between change in posterior pelvic tilt and change in hip external rotation ipsilateral to posterior pelvic tilt(r=.361, p<.05). A fair correlation was found between change in hip internal rotation ipsilateral to anterior pelvic tilt and change in hip external rotation ipsilateral to posterior pelvic tilt(r=.388, p<.05) and between change in hip internal rotation ipsilateral to posterior pelvic tilt and change in hip internal rotation ipsilateral to anterior pelvic tilt(r=.426. p<.05).

Keywords