The Application of Wedge Type Compensation Filter for Uniform Density on the Endoscopic Retrograde Pancreatography

내시경적 역행성 췌관 조영상의 균등한 농도를 위한 적절한 쐐기형 필터의 적용

  • 손순룡 (아산재단 서울중앙병원 방사선과) ;
  • 이희정 (아산재단 서울중앙병원 방사선과) ;
  • 이원홍 (아산재단 서울중앙병원 방사선과) ;
  • 조정찬 (아산재단 서울중앙병원 방사선과) ;
  • 류명선 (아산재단 서울중앙병원 방사선과) ;
  • 정홍량 (한서대학교 방사선학과)
  • Published : 2001.06.30

Abstract

Over-density of pancreatic duct tail part on the endoscopic retrograde pancreatogram results from patient's position and inserted air during the study. The aim of this paper is to decide the filter angle to obtain an uniform density. Endoscopic retrograde pancreatography was performed to 234 patients, and angled wedge filter was used differently. They are $10^{\circ}$ (47), $20^{\circ}$ (45), $30^{\circ}$ (50), and $40^{\circ}$ (50). We also did not use wedge filter to 42 patients. We decided reliance degree in 95%. The statistical difference was p<0.05. The patients' sex rate was 1.8 : 1 between 18 and 87 years old(average age 58 years). Their body girth was 18.71 cm on the average. Of total 234 patients, difference of right and left average density was 0.01 by $30^{\circ}$ wedge filter, -0.08 $40^{\circ}$ wedge filter and 0.27 non-wedge filter. These average values of difference density were very significant statistically, and standard deviation also was close to regular distribution. In conclusion, there is a usefulness of angled wedge filter for increasing diagnostic value of pancreatic duct tall part on the endoscopic retrograde pancreatogram.

Keywords