Journal of radiological science and technology (대한방사선기술학회지:방사선기술과학)
- Volume 24 Issue 1
- /
- Pages.5-9
- /
- 2001
- /
- 2288-3509(pISSN)
- /
- 2384-1168(eISSN)
The Application of Wedge Type Compensation Filter for Uniform Density on the Endoscopic Retrograde Pancreatography
내시경적 역행성 췌관 조영상의 균등한 농도를 위한 적절한 쐐기형 필터의 적용
- Son, Soon-Yong (Dept. of Diagnostic Radiology, AMC) ;
- Lee, Hee-Jeong (Dept. of Diagnostic Radiology, AMC) ;
- Lee, Won-Hong (Dept. of Diagnostic Radiology, AMC) ;
- Cho, Cheong-Chan (Dept. of Diagnostic Radiology, AMC) ;
- Ryu, Meung-Sun (Dept. of Diagnostic Radiology, AMC) ;
- Jung, Hong-Ryang (Dept. of Radiology, Hanseo University)
- 손순룡 (아산재단 서울중앙병원 방사선과) ;
- 이희정 (아산재단 서울중앙병원 방사선과) ;
- 이원홍 (아산재단 서울중앙병원 방사선과) ;
- 조정찬 (아산재단 서울중앙병원 방사선과) ;
- 류명선 (아산재단 서울중앙병원 방사선과) ;
- 정홍량 (한서대학교 방사선학과)
- Published : 2001.06.30
Abstract
Over-density of pancreatic duct tail part on the endoscopic retrograde pancreatogram results from patient's position and inserted air during the study. The aim of this paper is to decide the filter angle to obtain an uniform density. Endoscopic retrograde pancreatography was performed to 234 patients, and angled wedge filter was used differently. They are
Keywords