DOI QR코드

DOI QR Code

Non-elastic responses of tall steel buildings subjected to across-wind forces

  • Tamura, Yukio (Department of Architecture, Tokyo Institute Polytechnics) ;
  • Yasui, Hachinori (Urban Environment Research Center, Izumi Sohken Engineering Co., Ltd.) ;
  • Marukawa, Hisao (Urban Environment Research Center, Izumi Sohken Engineering Co., Ltd.)
  • 발행 : 2001.04.25

초록

This paper presents an analytical method which takes into account the non-linearity of individual members, and discusses some case study results. It also discusses the relationship between member non-elastic behavior and excitation duration, and the relationship between member fracture and overall structure behavior. It is clearly demonstrated that the frame already shows almost unstable behavior due to long-columnization just before the occurrence of a column fracture. Then, a column fracture immediately induces a structural collapse mechanism.

키워드

참고문헌

  1. AIJ (1993), Recommendation for Loads on Buildings, Architectural Institute of Japan.
  2. JABRP (1998), Recommendations on Loads for Performance Based Design, Japan Association for Building Research Promotion. (in Japanese)
  3. Ogawa, K. (1995), Research Report for Numerical Analysis, Steel Material Club & Building Research Institute, Annex B. (in Japanese)
  4. Ohkuma, T., Kurita, T. and Ninomiya, M. (1997), "Response estimation based on energy balance for elastoplastic vibration of tall building in across-wind direction", Structural Safety and Reliability. Proceedings of ICOSSAR'97, 1359-1366.
  5. Tamura, Y. (1995), "Numerical simulation program for structure response induced by wind loads - Technical Manual. Tamura Laboratory", Tokyo Institute of Polytechnics. (in Japanese)
  6. Tsujita, O., Hayabe, Y. and Ohkuma, T. (1997), "A study on wind-induced response for inelastic structure", Structural Safety and Reliability. Proceedings of ICOSSAR'97, 1359-1366.
  7. Tsukagoshi, H., Tamura, Y., Sasaki, A. and Kanai, H. (1993), "Response analyses on along-wind and acrosswind vibrations of tall buildings in time domain", Journal of Wind Engineering and Industrial Aerodynamics, 46-47, 497-506. https://doi.org/10.1016/0167-6105(93)90317-H

피인용 문헌

  1. Field Measurement of Wind Speeds and Wind-Induced Responses atop the Shanghai World Financial Center under Normal Climate Conditions vol.2013, 2013, https://doi.org/10.1155/2013/902643
  2. An efficient framework for the elasto-plastic reliability assessment of uncertain wind excited systems vol.58, 2016, https://doi.org/10.1016/j.strusafe.2015.09.001
  3. Free and forced motion in an asymmetric liquid-column oscillator vol.464, pp.2092, 2008, https://doi.org/10.1098/rspa.2007.0375
  4. A performance-based design framework for the integrated collapse and non-collapse assessment of wind excited buildings vol.150, 2017, https://doi.org/10.1016/j.engstruct.2017.07.030
  5. Wind Loading of Structures: Framework, Phenomena, Tools and Codification vol.12, 2017, https://doi.org/10.1016/j.istruc.2017.09.008
  6. Inelastic responses of wind-excited tall buildings: Improved estimation and understanding by statistical linearization approaches vol.159, 2018, https://doi.org/10.1016/j.engstruct.2017.12.041
  7. Probabilistic performance assessment of inelastic wind excited structures within the setting of distributed plasticity vol.84, pp.None, 2001, https://doi.org/10.1016/j.strusafe.2020.101923
  8. Performance-based wind design of tall buildings: concepts, frameworks, and opportunities vol.31, pp.2, 2020, https://doi.org/10.12989/was.2020.31.2.103
  9. Nonlinear Dynamic Response of Single-Degree-of-Freedom Systems Subjected to Along-Wind Loads. I: Parametric Study vol.147, pp.11, 2021, https://doi.org/10.1061/(asce)st.1943-541x.0003125
  10. Inelastic Performance of High-Rise Buildings to Simultaneous Actions of Alongwind and Crosswind Loads vol.148, pp.2, 2022, https://doi.org/10.1061/(asce)st.1943-541x.0003236
  11. Upper Limit of Aerodynamic Forces for Inelastic Wind Design vol.148, pp.2, 2001, https://doi.org/10.1061/(asce)st.1943-541x.0003260