DOI QR코드

DOI QR Code

Seismic test of modal control with direct output feedback for building structures

  • Lu, Lyan-Ywan (Department of Construction Engineering, National Kaohsiung First University of Science and Technology)
  • Published : 2001.12.25

Abstract

In this paper, modal control with direct output feedback is formulated in a systematic manner for easy implementation. Its application to the seismic protection of structural systems is verified by a shaking table test, which involves a full-scale building model and an active bracing system as the control device. Two modal control cases, namely, one full-state feedback and one direct output feedback control were tested and compared. The experimental result shows that in mitigating the seismic response of building structures, modal control with direct output feedback can be as effective and efficient as that with full-state feedback control. For practical concerns, the control performance of the proposed method in the presence of sensor noise and stiffness modeling error was also investigated. The numerical result shows that although the control force may be increased, the maximum floor displacements of the controlled structure are very insensitive to sensor noise and modeling error.

Keywords

References

  1. Andry, A.N., Shapiro, E.Y., and Chung, J.C. (1983), "Eigenvalue assignment for linear systems", IEEE Transaction on Aerospace and Electronic Systems, 19(5), 711-728.
  2. Balas, M.J. (1979), "Direct output feedback control of large space structures", J. Astronaut. Sci., 27(2), 157-180.
  3. Baruh, H. (1987), "A recursive pole placement method for large flexible structures", Proc. of ASME Design Technology Conference, 11th Biennial Conference on Mechanical Vibration and Noise, 79-84.
  4. Bendat, J.S., and Piersol, A.G. (1991), Random Data, 2nd edn., John Wiley & Sons Inc., Singapore.
  5. Chang, C.-C., and Yu, L.-O. (1998), "A simple optimal pole location technique for structural control", Eng. Struct., 20(9), 792-804. https://doi.org/10.1016/S0141-0296(98)80004-7
  6. Chang, M.I.I. and Soong, T.T. (1980), "Optimal controller placement in modal control of complex system", J. Math. Anal. and Appl., 75, 340-358. https://doi.org/10.1016/0022-247X(80)90084-0
  7. Clough, R.W., and Penzien, J. (1993), Structural Dynamics, 2nd edn., McGraw Hill Inc., 492-498.
  8. Davison, E.J. (1970), "On pole assignment in linear system with incomplete state feedback", IEEE Transactions on Automatic Control, 15, 348-351. https://doi.org/10.1109/TAC.1970.1099458
  9. Davison, E.J., and Wang, S.H. (1975), "On pole assignment in linear multivariable systems using output feedback", IEEE Transactions on Automatic Control, 20, 516-518. https://doi.org/10.1109/TAC.1975.1101023
  10. Dyke, S.J., Spencer, B.F., Quast, P., Sain, M.K., Kaspari, D.C., and Soong, T.T. (1996a), "Acceleration feedback control of MDOF structures", J. Eng. Mech., ASCE, 122(9), 907-918. https://doi.org/10.1061/(ASCE)0733-9399(1996)122:9(907)
  11. Dyke, S.J., Spencer, B.F., Quast, P., Kaspari, D.C., and Sain, M.K. (1996b), "Implementation of an active mass driver using acceleration feedback control", Microcomputers in Civil Engineering: Special Issue on Active and Hybrid Structural Control, 11, 305-323.
  12. Kautsky, J., and Nichols, N.K. (1985), "Robust pole assignment in linear state feedback", Int. J. Control, 41(5), 1129-1155. https://doi.org/10.1080/0020718508961188
  13. Kimura, H. (1975), "Pole assignment by gain output feedback", IEEE Transactions on Automatic Control, 20, 509-516. https://doi.org/10.1109/TAC.1975.1101028
  14. Kurata, N., Kobori, T., Motoichi, T., Niwa, N., and Midorikawa, H. (1999), "Actual seismic response controlled building with semi-active damper system", Earthq. Eng. and Struct. Dyn., 28(11), 1427-1447. https://doi.org/10.1002/(SICI)1096-9845(199911)28:11<1427::AID-EQE876>3.0.CO;2-#
  15. Lu, L.Y., Bain, J.J., and Chung, L.L. (1999), "Use of the active member concept in vibration mitigation of seismic structures", Eng. Struct., 21(4), 341-351. https://doi.org/10.1016/S0141-0296(97)00184-3
  16. Lu, L.Y., Utku, S., and Wada, B.K. (1993), "Vibration suppression for large scale adaptive truss structures using direct output feedback control", J. of Intelligent Mater. Sys. and Struct., 4(3), 385-397. https://doi.org/10.1177/1045389X9300400312
  17. Maghami, P.G., and Juang, J.N. (1989), "Efficient eigenvalue assignment for large space structures", Proc. of AIAA/ASME/ASCE/AHS 30th Structures, Structural Dynamics, and Materials Conference, Mobil, AL, USA, 2037-2045.
  18. Meirovitch, L. (1990), Dynamic and Control of Structures, John Wiley & Sons, New York, USA.
  19. Moore, B.C. (1976), "On the flexibility offered by state feedback in multivariable systems beyond closed loop eigenvalue assignment", IEEE Transaction on Automatic Control, 21, 689-692. https://doi.org/10.1109/TAC.1976.1101355
  20. Nishitani, A. (1998), "Application of active structural control in Japan", Progress in Structural Engineering and Materials, 1(3), 301-307. https://doi.org/10.1002/pse.2260010312
  21. Öz, H., and Meirovitch, L. (1980), "Optimal modal-space control of flexible gyroscopic systems", J. Guidance and Control, 3(3), 218-226. https://doi.org/10.2514/3.55975
  22. Porter, B., and D'Azzo, J.J. (1978), "Closed loop eigenstructure assignment by state feedback in multivariable linear system", Int. J. of Control, 27(3), 487-492. https://doi.org/10.1080/00207177808922386
  23. Simon, J.D., and Mitter, S.K. (1968), "A theory of modal control", Information and Control, 3, 316-353.
  24. Soong, T.T. (1990), Active Structural Control - Theory and Practice, Longman, London (U.K.).
  25. Srinathkumar, S. (1978), "Eigenvalue/eigenvector assignment using direct output feedback", IEEE Transaction on Automatic Control, 23(1), 79-81. https://doi.org/10.1109/TAC.1978.1101685
  26. Varga, A. (1981), "A Schur method for pole assignment", IEEE Transactions on Automatic Control, 26(2), 517-519. https://doi.org/10.1109/TAC.1981.1102605
  27. Wonham, W.M. (1967), "On pole assignment in multi-input, controllable linear systems", IEEE Transaction on Automatic Control, 12, 660-665. https://doi.org/10.1109/TAC.1967.1098739

Cited by

  1. An Experimental Study of Semiactive Modal Neuro-control Scheme Using MR Damper for Building Structure vol.19, pp.9, 2008, https://doi.org/10.1177/1045389X07083024
  2. Modeling and experimental verification of a variable-stiffness isolation system using a leverage mechanism vol.17, pp.12, 2011, https://doi.org/10.1177/1077546310395976
  3. A Semi-active piezoelectric friction damper vol.44, pp.3, 2015, https://doi.org/10.1002/eqe.2469
  4. Implementation of Modal Control for Seismically Excited Structures using Magnetorheological Dampers vol.131, pp.2, 2005, https://doi.org/10.1061/(ASCE)0733-9399(2005)131:2(177)
  5. Semi-active modal control for seismic structures with variable friction dampers vol.26, pp.4, 2004, https://doi.org/10.1016/j.engstruct.2003.10.012
  6. A General Method for Semi-Active Feedback Control of Variable Friction Dampers vol.15, pp.5, 2004, https://doi.org/10.1177/1045389X04041365
  7. Stiffness controllable isolation system for near-fault seismic isolation vol.30, pp.3, 2008, https://doi.org/10.1016/j.engstruct.2007.05.022
  8. Modal-based LQG for smart base isolation system design in seismic response control vol.20, pp.5, 2013, https://doi.org/10.1002/stc.1490