DOI QR코드

DOI QR Code

Effect of shear wall location in rigid frame on earthquake response of roof structure

  • Ishikawa, Koichiro (Department of Architecture and Civil Engineering, Fukui University) ;
  • Kawasaki, Yoshizo (Department of Architecture and Civil Engineering, Fukui University) ;
  • Tagawa, Kengo (Department of Architecture and Civil Engineering, Fukui University)
  • Published : 2001.06.25

Abstract

The purpose of this study is to investigate the effect of the shear wall location in rigid frames on the dynamic behavior of a roof structure due to vertical and horizontal earthquake motions. The study deals with a gabled long span beam supported by two story rigid frames with shear walls. The earthquake response analysis is carried out to study the responses of the roof: vibration mode, natural period, bending moment and horizontal shear force of the bearings. The study results in the following conclusions: First, a large horizontal stiffness difference between the side frames is caused by the shear wall location, which results in a large vertical vibration of the roof and a large shear force at the side bearings. Second, in this case, the seismic design method for ordinary buildings is not useful in determining the distribution of the static equivalent loads for the seismic design of this kind of long span structures.

Keywords

References

  1. Blandford, G.E. (1997), "Review of progressive failure analyses for truss structures", J. of Struct. Eng., 123(2), 122-129. https://doi.org/10.1061/(ASCE)0733-9445(1997)123:2(122)
  2. Eppo, A.S.K., and Karamanos, S.A. (1993), "Seismic design of double layer space grids and their supports", Space Structures 4, Proc. of the Fourth Int. Conf. of Space Struct., Park, G.A.R. ed, 1, Thomas Telford, 476-484.
  3. Eurocode No.8 (1998), "Design of structures in seismic regions", European Committee for Standardization (CEN) Standards.
  4. Rosenblueth, E. (1980), Design of Earthquake Resistant Structures, Pentech Press.
  5. SEAOC (1996), "Recommended lateral force requirements and comenmentary", Structural Engineers Association of California's (SEAOC) Recommendations and Commentary for Earthquake-Risistant Design of Structures, SEAOC Blue Book, SESP 96.
  6. The Architectural Institute of Japan (1993), "Earthquake motion and ground conditions", AIJ edn., Japan, 471- 483.
  7. The Architectural Institute of Japan (1997), "Report on the Hanshin-Awaji earthquake disaster", Structural Damage to Shell and Spatial Structures, AIJ edn., Building Series, Japan, 3, 219-346.
  8. Yigang, Z., and Lan, T.T. (1985), "A practical method of space frames under vertical earthquake", J. of Building Struct., 5.