Journal of the Korea institute for structural maintenance and inspection (한국구조물진단유지관리공학회 논문집)
- Volume 5 Issue 4
- /
- Pages.155-160
- /
- 2001
- /
- 2234-6937(pISSN)
- /
- 2287-6979(eISSN)
Level Calibration of Ultrasonic Nondestructive Testing Considering Flaw Position
불연속부의 위치를 고려한 초음파비파괴검사 등급보정
- Received : 2001.02.07
- Published : 2001.10.31
Abstract
KS-code(KS B 0896) for nondestructive ultrasonic testing classifies the quality level by relative flaw size only. But flaw position is more important than the flaw size. Test blocks having artificial holes near surface show lower yield load than the blocks having deeply located holes from the surface. So, level calibration table was proposed for classifying the quality level of welded steel structures.