Level Calibration of Ultrasonic Nondestructive Testing Considering Flaw Position

불연속부의 위치를 고려한 초음파비파괴검사 등급보정

  • 신병철 (동의대학교 공과대학) ;
  • 송호산 (동의대학교 공과대학) ;
  • 정화영 (동의대학교 산업기술개발연구소)
  • Received : 2001.02.07
  • Published : 2001.10.31

Abstract

KS-code(KS B 0896) for nondestructive ultrasonic testing classifies the quality level by relative flaw size only. But flaw position is more important than the flaw size. Test blocks having artificial holes near surface show lower yield load than the blocks having deeply located holes from the surface. So, level calibration table was proposed for classifying the quality level of welded steel structures.

Keywords