Development of Performance Analysis System (NOPAS) for Turbine Cycle of Nuclear Power Plant

  • Published : 2001.02.01

Abstract

We have needs to develop a performance analysis system that can be used in domestic nuclear power plants to determine performance status of turbine cycle. We developed new NOPAS system to aid performance analysis of turbine cycle . Procedures of performance calculation are improved using several adaptations from standard calculation algorithms based on ASME (American Society of Mechanical Engineers) PTC (Performance Test Code). Robustness in the performance analysis is increased by verification & validation scheme for measured input data. The system also provides useful aids for performance analysis such as graphic heat balance of turbine cycle and components, turbine expansion lines, automatic generation of analysis reports.

Keywords

References

  1. American Society of Mechanical Engineers Performance Test Code 6, 'Steam Turbines,' ASME (1976)
  2. American Society of Mechanical Engineers Performance Test Code 6A, 'Appendix A to Test Code for Steam Turbines,' ASME (1982)
  3. American Society of Mechanical Engineers Performance Test Code 12.1, 'Closed Feed water Heaters', ASME (1978)
  4. American Society of Mechanical Engineers Performance Test Code 12.2, 'Steam Condensing Apparatus,' ASME (1983)
  5. Glorian, D., 'Performance of Thermal Generating Plants Worldwide: Current Situation and Outlook', 8th Int. Conference & Exhibition for the Power Generating Industries, pp. 337-350 (1995)
  6. Munchausen, J. H., 'EPRI Performance Enhancement Program,' Proceedings of the American Power Conference, pp. 519-521 (1995)
  7. Bae, Y. I., Kim, H. Y., Mun, S. C., and Kim, S. K., 'Neural Network Model of Turbine Cycle Process', Korea Power Engineering Co. (KOPEC) Power Engineering Report, 16-1, pp. 6-14 (1994)
  8. Spencer, R.C., Cotton, K.C., Cannon, C.N., 'A Method for Predicting the Performance of Steam Turbine-Generators, 16,500KW and Larger,' General Electric Co. Report (1974)
  9. British Electricity International, 'Modern Power Station Practice: Volume G Station Operation and Maintenance,' British Electricity International (1991)
  10. Kim, S.K. and Han, S.T., 'A Study on The Computerization Of Performance Evaluation For Thermal Power Plant,' 3rd KSME-JSME Thermal Engineering Conference, 3, pp. 401-406 (1996)
  11. Draper, N.R., smith, H., 'Applied Regression Analysis,' 2nd Ed., John Wiley & Sons (1976)