The Secondary Chamber Pressure Characteristics of Sonic/Supersonic Ejector-Diffuser System

음속/초음속 이젝터 시스템의 2차정체실 압력특성

  • 이준희 (안동대학교 기계공학과 대학원) ;
  • 최보규 (㈜동화엔텍 기술연구소) ;
  • 김희동 (안동대학교 기계공학부) ;
  • 박종호 (충남대학교 기계공학과)
  • Published : 2001.12.01

Abstract

The present study is an experimental work of the soni $c^ersonic air ejector-diffuser system. The pressure-time dependence in the secondary chamber of this ejector system is measured to investigate the steady operation of the ejector system. Six different primary nozzles of two sonic nozzles, two supersonic nozzles, petal nozzle, and lobed nozzle are employed to drive the ejector system at the conditions of different operating pressure ratios. Static pressures on the ejector-diffuser walls are to analyze the complicated flows occurring inside the system. The volume of the secondary chamber is changed to investigate the effect on the steady operation. the results obtained show that the volume of the secondary chamber does not affect the steady operation of the ejector-diffuser system but the time-dependent pressure in the secondary chamber is a strong function of the volume of the secondary chamber.er.

본 연구는 음속/초음속 공기이젝터 시스템을 통하는 유동을 실험적으로 조사한 것으로, 이젝터 시스템의 2차정체실 압력-시간의 의존성을 조사하였다. 본 실험에서 적용된 1차구동 노즐은 총 6가지 형태로, 두 개의 음속노즐과 두 개의 초음속 노즐 그리고 페탈노즐 및 로브형 노즐이 사용되었다. 실험에서는 이젝터-디퓨저 벽면에서 압력을 측정하였으며, 2차 정실실의 체적이 이젝터 내부에 미치는 영향을 조사하기 위하여, 2차 정체실의 체적을 변화시켰다. 그 결과 2차정체실의 체적은 이젝터 시스템의 정상 작동에는 영향을 미치지 않았지만, 2차정체실에서의 압력-시간 의존성은 2차정체실의 체적에 큰 영향을 받는다는 것을 알았다.

Keywords