SAR Analysis for Test Positions of Mobile Phone

휴대전화의 시험위치에 따른 SAR 분석

  • Published : 2001.12.01

Abstract

There has been an increase in the public concern about possible health risks by electromagnetic exposure from mobile phones. Recently, several SAR measurement procedures have been proposed to demonstrate the compliance of mobile phone with safety limits. To determine the maximum localized SAR of a test mobile phone, the electric field distribution is measured in the head phantom with simulated tissue liquid using the probe The important parameters in SAR measurement are the E-field probe, the shape and size of phantom, the electrical parameters of simulated tissue liquid, and test position, etc. Therefore, in order to setup the measurement standard, the studies on these factors are required. In this paper, the effects of the maximum localized SAR on the test positions of mobile phones were analyzed by the numerical computation and the SAR measurement. From the results, the worst condition of commonly used positions was determined and the touch and tilted positions were adopted as test positions of the domestic SAR measurement standard.

최근, 휴대전화로부터 복사되는 전자파 노출에 대한 건강 위험성에 관한 국민적 관심이 높아지고 있고, 그에 따라 휴대전화가 전자파 인체보호기준의 적합성 여부를 평가하기 위한 전자파흡수율 측정 방법이 제안되어 왔다. 피시험기기인 휴대전화에 대한 국부 전자파흡수율은 전기장 프로브를 사용하여 모의조직으로 채워진 모의 인체 두부에서 전기장 분포를 측정함으로써 얻어진다. 전자파흡수율 측정에 요소가 되는 전기장 프로브, 모의인체의 형상과 크기, 모의조직의 전기정수 그리고 시험위치 등에 따라 측정값이 달라지므로 전자파흡수율 측정 기준을 설정하기 위해서는 이들 요소에 대한 연구가 요구된다. 본 논문에서는 휴대전화의 시험위치에 따른 전자 파흡수율 변화를 수치해석과 측정을 통해 분석하였으며, 통상 사용위치에서 최악의 조건을 조사하였다. 본 결과를 바탕으로 국내 전자파흡수율 측정 기준의 시험위치로서 접촉위치와 경사위치를 채택하였다.

Keywords

References

  1. FCC OET Bulletin 65(Edition 97-01) Evaluating compliance with FCC guidelines for human exposure to radiofrequency electromagnetic fields
  2. ARIB STD-T56 Specific Absortion Rate(SAR) Estimation for Cellular Phone
  3. CENELEC prES59005 Considerations for evaluation of human exposure to electromagnetic fields(Emfs) from mobile telecommunication equipment(MTE) in frequency range 30 MHz~6 GHz
  4. CENELEC prEN 50361 Basic standard for the measurement of Specific Absorption Rate related to human exposure to electromagnetic fields from mobile phone(300 MHz~3 GHz)
  5. IEEE SCC34 SC2 P1528 Draft Recommended Practice for Determining the Spatial-Peak Specific Absorption Rate(SAR) in the Human Body Due to Wireless Communication Devices: Experimental Techniques
  6. 전자공학회논문지 v.37 no.11 이동통신단말기에 노출된 인체 두부에 따른 전자파 비흡수율 비교 이애경;최형도;최재익
  7. 정보통신부 고시 제2000-93호 전자파흡수율 측정기준
  8. Proceeding of 1998 Asia-Pacific Microwave Conference v.2 Electromagnetic energy absorption in a human head for a cellular phone at 835 MHz Ae-Kyoung Lee;Jin-Suk Kim;Hyung-Do Choi;Kwang-Yun Cho