Abstract
In this paper, a multiple comparison was proposed to minimize the amount of coolant. And new coolant level, called "low level", was suggested to show usefulness of multiple comparison for experiments. The amount of this levee is about 1/4 of conventional coolant amount-called "high level", and dry cutting is called "none level". Using these coolant levels, the cutting temperatures of each coolant level in turning process were analyzed by analysis of variance(ANOYA)-test and a multiple comparison. As the result of ANOVA-test, we have just known that the average of temperature of each coolant level is not equal. However by Tukey's HSD, one of multiple comparison. it was analyzed that the average of temperature of low level is similar to that of high levee and different from that of none level.erent from that of none level.