A Study of Nitrogen Dioxide Concentration in Industrial Areas

공단지역내 이산화질소농도에 관한 연구

  • 손부순 (순천향대학교 환경보건학과) ;
  • 김우재 (한양대학교 환경 및 산업의학연구소) ;
  • 김윤신 (한양대학교 환경 및 산업의학연구소)
  • Published : 2001.09.01

Abstract

This study were conducted to estimate property of nitrogen dioxide concentration at industrial areas in Korea. The nitrogen dioxide concentrations were measured for 50 dwellings at Ulsan and Yeochon, respectively using the nitrogen dioxide filter badge forming the passive sampler from summer time 1998 to winter time 1999. The major results obtained from this study were as follows: 1. The mean indoor, outdoor, and personal concentrations of nitrogen dioxide during summer time 1998 in Ulsan were 28.9 ppb, 24.8 ppb, 24.8 pub, respectively. 2. The mean indoor, outdoor, and personal concentrations of nitrogen dioxide during winter time 1999 in Yeochon were 11.4 ppb, 12.5 ppb, 15.5 ppb, respectively. 3. The mean concentration of nitrogen dioxide during winter time 1998 were higher than the corresponding levels during summer time 1997 in Ulsan. 4. The mean concentration of nitrogen dioxide in Ulsan were in general higher than the corresponding levels in Yeochon. 5. This results in slightly positive correlation among indoor, outdoor, and personal nitrogen dioxide concentrations for summer time in Ulsan, then it statistical significance is showed(p <.05). These results suggest that nitrogen dioxide concentrations in industrial areas seem to be affected by traffic density and conditions of industrialization.

Keywords

References

  1. 대기오염물질의 위해성 평가 및 관리기술 환경부
  2. Report SAB-EC 90-021 Reducing Risk : Setting Priorities and strategies for Environmental Protection U.S. EPA Science Advisory Board
  3. Res. Rep. Halth Eff. Inst. v.58 Nitrogen dioxide and respiratory illness in children. Part Ⅳ: Effect of housing and meteorologic factors on inddor nitrogen dioxide concentrations Spengler, J.D.;Schwab, M.;McDermott, A.;Lambert, W.E.;Samat, J.M.
  4. J. Air Pollut. Control. Assoc. v.39 Indoor exposure to airborne particles and nitrogen dioxide during an air pollution episode. Hoek, G.;Brunekreef, B.;Hofschreuder, P.
  5. Environmental International v.19 Sampling rate evaluation for NO₂badge : (Ⅱ) in personal monitoring Kiyoung, Lee;Yukio Yanagisawa;John D. Spengler;Haluk Ozkaynak
  6. 한국대기환경학회지 v.14 no.4 도시지역 실내환경 유형별 공기질 독성평가 백성옥
  7. 1990 연간보고서 EPA
  8. 1996년 울신시 통계연보 통계청
  9. 한국대기보전학회지 v.14 no.2 여천공업단지 봄, 가을 대기 중 휘발성 유기화합물 농도 비교 연구 김영성;송철한;심상규;김용표;문길주
  10. Environ. Int. v.8 A badge-type personal sampler for measurement of personal exposure to NO₂and NO in ambient air Yanagisawa, Y.;Nishimura, H.
  11. Environ. Int. v.12 Measurement of Indoor and Personal Exposure to Nitrogen Dioxide in Korea Kim, Y.S.;Spengler, J.D.;Yanagisawa
  12. 이산화질소의 실내농도 및 개인피폭량에 관한 연구 박상희
  13. 한국환경위생학회지 v.17 no.2 서울시 택시기사의 이산화질소 개인피폭량에 관한 연구 김윤신;전준민;홍승철
  14. JAPCA v.32 Indoor outdoor air Quality relationship-A critical review Yocom, J.D.
  15. 호흡성분진 중 금속성분의 실내외농도에 관한 조사 연구 장지훈
  16. Environmental Pollution v.110 Analysis of air pollution in two major korean cities ; trends seasonal variations, daily 1-hour maximum versus other hour-based concentrations, and standard exceedances W.K. Jo.;I.H. Yoon.;C.W. Nam
  17. 대한위생학회지 v.15 no.2 시간활동도를 이용한 이산화질소 개인노출예측 양원호;이기영;손현석;정문호(등)
  18. 대한위생학회지 v.12 no.3 서울시 버스터미널의 이산화질소 및 아황산가스농도 손부순;장봉기;김영규(등)
  19. 대기오염개론 우원기
  20. 한국대기환경학회지 v.6 no.1 일부지역의 실내공기오염도와 건강에 미치는 영향에 관한 연구 신동천;이효민;김종만;정용(등)
  21. Atmospheric Environ-ment v.34 Small area variations in ambient NO₂concentrations in four European areas Erik Lebert;David Briggs;Hans van Reeuwijk(et al.)
  22. 울산시 통계연보
  23. 여천시 통계연보
  24. Building and Environment v.35 A study of personal exposure to nitrogen dioxide using passive samplers Christopher Y.H.;Chao, Anthony Law
  25. Occupational and Environmental Medicine v.57 Personal exposure of children to nitrogen dioxide relative to concentrations in outdoor air Linaker C.H.;Chanhan A.J.;Inskip H.M.;Holgate S.T.;Coggon D.