Abstract
Electromagnetic field characteristics of Reverberation chamber, which could be applicable for an alternative test facility of electromagnetic interference and radiated electromagnetic susceptibility have been investigated. To obtain the required field uniformity of reverberation chamber, Schroeder method Quadratic Residue Diffuser was designed to be applied to chamber. In this paper, 3 different types of diffusers depending on diffuser's periodic direction have been used to investigate field characteristics of each type by using FDTD numerical method. The results show all 3 types of reverberation chambers have below $\pm$3 dB tolerance of field uniformity characteristics, and the symmetrical, type 3, structure show better results among them.
본 논문에서는 전자파 장해 및 복사내성 측정의 대용 시험시설로서 활용될 수 있는 전자파 잔향실의 전자기장 특성에 관하여 연구되었다. 전자파 잔향실 내부에서의 필드 균일성을 확보하기 위하여, Shroeder 방식의 Quadratic Residue 확산기(diffuser)를 설계한 후, 확산기의 방향에 따른 3가지 배열 형태로 잔향실 내부에 적용하여, 필두 분포를 해석하였다. FDTD(Finite-Difference Time-Domin) 수치해석 방식을 이용하여 잔향실 내부의 필드 특성을 연구한 결과 확산기를 부착한 3가지 형태 모두 최대 변화범위 $\pm$3 dB 이내의 필드 균일도를 나타내었으며, type 3, 대칭형 구조의 확산기 형태가 효율이 가장 우수하다는 결과를 나타내었다.