A Study of Characteristics of NOx Emission in Lobed Burner

로브형 버너에서의 NOx 배출 특성에 관한 연구

  • 조한창 (포항산업과학연구원 에너지/화성연구팀) ;
  • 조길원 (포항산업과학연구원 에너지/화성연구팀) ;
  • 이용국 (포항산업과학연구원 에너지/화성연구팀)
  • Published : 2001.06.30

Abstract

To evaluate the effect of lobed structure on pollutant emission, an experimental study examines NOx and CO emissions associated with four burner geometries, such as a conventional circular burner and three lobed ones. Rapid mixing allowed by the lobed burner to produce lean premixed flames, with narrower flame stability diagram than for the conventional circular one. Conventional circular burner of wide and uniform burner rim has an advantage of flame stabilization. Correlation on fuel discharge velocity for flame blowout should be included a variable related to the wall effect of the burner. NOx emission reduces by about 5% at the burner with lobed structure in fuel discharge side compared to conventional circular one. This is due to lower flame temperatures through flame elongation and increased radiative heat losses, caused by partially luminous flame in flame front. Meanwhile, at the burner with lobed structure in air discharge side and both fuel and air discharge sides, NOx emission somewhat increases with reduced radiative heat losses in spite of flame elongation. Therefore, the rapid mixing by lobed structure does not always have an advantage on NOx reduction.

Keywords