HARDNESS OF COMPOSITE RESIN CURED BY HIGH INTENSITY HALOGEN LIGHT

고강도 할로겐광으로 중합한 복합레진 수복재의 경도

  • Park, Jong-Seok (Department of Pediatric Dentistry, Wonkwang Dental Research Institute, College of Dentistry, Wonkwang University) ;
  • Lee, Kwang-Hee (Department of Pediatric Dentistry, Wonkwang Dental Research Institute, College of Dentistry, Wonkwang University) ;
  • Kim, Dae-Eup (Department of Pediatric Dentistry, Wonkwang Dental Research Institute, College of Dentistry, Wonkwang University) ;
  • Kim, Seong-Hyeong (Department of Pediatric Dentistry, Wonkwang Dental Research Institute, College of Dentistry, Wonkwang University) ;
  • Ahn, Ho-Young (Department of Pediatric Dentistry, Wonkwang Dental Research Institute, College of Dentistry, Wonkwang University)
  • 박종석 (원광대학교 치과대학 소아치과학교실 원광치의학연구소) ;
  • 이광희 (원광대학교 치과대학 소아치과학교실 원광치의학연구소) ;
  • 김대업 (원광대학교 치과대학 소아치과학교실 원광치의학연구소) ;
  • 김성형 (원광대학교 치과대학 소아치과학교실 원광치의학연구소) ;
  • 안호영 (원광대학교 치과대학 소아치과학교실 원광치의학연구소)
  • Published : 2001.08.31

Abstract

The purpose of this study was to compare the effect of the high intensity halogen light $(850\sim1000mW/cm^2)$ with that of the conventional halogen light $(400mW/cm^2)$ on the hardness of composite resin. Three resin composites (Z-100, 3M, U.S.A. : Tetric Ceram, Vivadent, Liechtenstein; SureFil, Dentsply, U.S.A.) were filed in the stainless steel moulds which were 4mm in diameter and 2, 3, 4, and 5mm in depth, respectively. They were cured under the four different modes : (1) conventional mode, 40 seconds at $400mW/cm^2$; (2) 'ramp' mode, 10 seconds at 100 to $1000mW/cm^2$ plus 10 seconds at $1000mW/cm^2$; (3) 'boost' mode, 10 seconds at $1000mW/cm^2$; and (4) 'standard' mode, 20 seconds at $850mW/cm^2$. The surface hardnesses of the top and the bottom of the resin samples were measured with a microhardness tester (MXT70, Matsuzawa, Japan). The top surface hardness was not significantly different among the curing modes. The bottom surface hardness was generally the highest in the conventional mode and the lowest in the high intensity boost mode. There was no significant difference in the bottom surface hardness between the conventional mode and the high intensity standard mode in 2mm depth. The results suggest that the curing time of the high intensity halogen light $(850mW/cm^2)$ should be at least 20 seconds to produce the equal level of the bottom surface hardness of 2mm resin composite as compared to the hardness produced by the conventional halogen light $(400mW/cm^2)$.

복합레진의 광중합시간 단축과 관련하여 최근에 개발된 고강도 할로겐광 중합기를 기존의 중강도 할로겐광 중합기와 비교 평가하기 위하여, 세 종류의 광중합용 복합레진을 두께가 2, 3, 4, 5mm인 스테인레스 스틸 몰드에 충전하고, 레진 상면을 중강도 할로겐광은 (1) $400mW/cm^2$으로 40초간 고강도 할로겐광은 (2) 10초동안 $100mW/cm^2$부터 $1000mW/cm^2$까지 출력량이 증가하면서 중합하고 다음 10초동안 $1000mW/cm^2$로 중합하는 ramp 모드로 20초간, (3) $1000mW/cm^2$의 boost 모드로 10초간, (4) $850mW/cm^2$의 표준 모드로 20초간 조사하고, 상면과 하면의 표면경도를 미세경도측정기로 측정한 후 실험군간의 차이를 분석하였다. 레진 상면의 경도는 중합광의 강도와 중합시간 및 레진 두께에 따른 차이가 없었다(유의수준 0.05, 이하 동일). 레진 하면의 경도는, 두께 2mm의 중강도군(1)을 제외하고, 상면의 경도보다 낮았다. 레진 하면의 경도는 두께 2mm에서 중강도군(1)이 ramp군(2) 및 boost군(3)보다 높았고 중강도군(1)과 표준군(4) 간 및 ramp군(2)과 boost 군(3) 간에 차이가 없었으며, 두께 3mm에서 중강도군(1)이 가장 높았고 표준군(4)이 boost군(3)보다 높았다. 따라서, 복합레진의 중합 깊이 측면에서 볼 때, $1000mW/cm^2$의 고강도 할로겐광을 10초간 조사한 것은 $400mW/cm^2$의 중강도 할로겐 광을 40초간 조사한 것에 미치지 못하였으며, 레진 두께 2mm이내인 경우에는 $850mW/cm^2$의 고강도 할로겐광을 20초간 조사함으로써 $400mW/cm^2$의 중강도 할로겐광을 40초간 조사한 것과 대등한 중합을 일으킬 수 있었다.