Sensory Nerve Conduction Velocity of Median Proper Palmar Digital Nerve Recorded by Bar Electrode

막대전극을 이용하여 기록한 정중고유손바닥쪽 손가락신경의 감각신경전도속도

  • Kwak, Kyo Ho (Department of Neurology, School of Medicine, Catholic University of Taegu-Hyosung) ;
  • Lee, Dong Kuck (Department of Neurology, School of Medicine, Catholic University of Taegu-Hyosung)
  • 곽규호 (대구효성가톨릭대학교 의과대학 신경과학교실) ;
  • 이동국 (대구효성가톨릭대학교 의과대학 신경과학교실)
  • Published : 2000.05.30

Abstract

Background: There has been few electrophysiologic studies in median proper palmar digital nerve(PPDN). Bar electrode may be a useful tool to evaluate the pathophysiologic state of the distal peripheral nerves. Objectives : To evaluate sensory nerve conduction velocities(NCVs) of median PPDNs in normal controls and carpal tunnel syndrome(CTS) patients by bar electrode, and clarify the usefulness of the bar electrode. Methods : We checked NCV of each median PPDN of thumb(D1), index(D2) and middle finger(D3) in normal controls(68 hands) and CTS patients(95 hands) by bar electrode. The each mean NCV of both groups were compared to find the correlation between them. Results : The mean NCV of each median PPDN in control group were $38.7{\pm}4.2$(D1), $32.0{\pm}4.6$(D2), $34.2{\pm}4.4$(D3) m/sec, and in CTS group were $35.3{\pm}8.9$(D1), $20.2{\pm}5.2$(D2), $20.2{\pm}5.1$(D3) m/sec orderly. There were significant differences between mean NCV of each finger in control group(p=0.0001), but not between each left and right finger(p>0.05). The differences between each mean NCV of control and CTS were significant in all 3 fingers(p=0.0014, 0.0000, 0.0000). Conclusion : Bar electrode is a useful tool to evaluate the pathophysiologic state of the median PPDNs in normal controls and CTS patients.

저자들은 정상 대조군과 CTS 환자군을 대상으로 막대전극을 이용하여 M P P D N의 감각신경전도검사를 실시하여 다음과 같은 결과를 얻었다. 1. MPPDN의 감각신경전도속도의 정상범위는 $38.7{\pm}4.2$(D1), $32.0{\pm}4.6$(D2), $34.2{\pm}4.4$(D3) m/sec로서 서로 유의한 차이가 있었다. 2. MPPDN의 감각신경전도속도의 정상범위는 좌우에서 서로 유의한 차이가 없었다. 3. CTS 환자에서 측정한 MPPDN의 감각신경전도속도는 각각 $35.3{\pm}8.9$(D1), $20.2{\pm}5.2$(D2), $20.2{\pm}5.1$(D3) m/sec로서 대조군에서 얻은 정상범위와 유의한 차이가 있었다.

Keywords