초록
The person' spending time in underground s[aces within indoor environment show a tendency to increase every year, but in Korea, levels and sources of pollutant in underground spaces have not been well-characterized. Therefore, as part or a larger indoor environmental study, conducted at subway station in Seoul, nitrogen dioxide was measured using passive samplers in 16 subway stations, 2 tunnels and 70 workers of subway station. The mean concentrations of nitrogen dioxide in subway stations were $27.87{\pm}7.15$ ppb at station office, $35.76{\pm}8.35$ ppb at platform, $52.60{\pm}13.04$ ppb at outdoor, respectively, and the Indoor/Outdoor ratio were 0.49~0.93. The mean concentrations of nitrogen dioxide in tunnels were $44.91{\pm}4.67$ ppb in Chunggye-Nowon tunnel with a single track, $42.55{\pm}3.33$ ppb in Mokkol-Taenung tunnel with double track, respectively, and as a result of t-test, a single track levels were higher than double track levels(p<0.05). The mean personal exposure of the subject of station workers was $29.40{\pm}9.75$ ppb.