The Evaluation of NOx Emission Factor from Large Combustion Facilities in Seoul

서울지역 대형연소시설에서의 질소산화물 배출계수 산정

  • Published : 2000.12.01

Abstract

The emission factor of nitrogen oxides(NOx) was evaluate to clarify the characteristics of NOx emitted from seven large combustion facilities in seoul area. The emission factors of NOx at A-1 and A-2 facilities of internal combustion engine were 66.957kgNOx/ton and 20.913kgNOx/ton, respectively. The emission factor of A-1 facility was higher than that of A-2 facility even same internal combustion engine, because A-1 facility adopted SCR(selective catalystic reactor) for reduction of NOx emission factor of A-2, A-4, and A-7 power generation boiler facilities were 4.300kgNOx/ton, 2.460kgNOx/ton and 1.796kgNOx/ton, respectively. The capacity of A-2 facility was about two times than that of A-4 and A-7. These emission factors were lower than those at facilities in other areas of korea, because of using low NOx burner of power generation boiler. The emission factors of NOx at A-3 and A-6 incinerator facilities were 0.147kgNOx/ton and 0.221kgNOx/ton which were lower than other facilities, respectively, because these facilities incinerate municipal solid waste of low heating value and uwe SCR for reducing NOx concentration.

Keywords

References

  1. Industrial and Engineering Chemistry v.44 no.6 Chemistry and Physiology of Los Angeles Smog Haggen Smith, A.J.
  2. AP-42(Fifth Edition) v.1 U.S. EPA
  3. National Air Pollution Emission Estimates U.S. EPA
  4. Environmental Assessment of NOx Control on a Compression Ignition Large Bore Reciprocating Internal Combustion Engine Castaldini, C.
  5. Acta, Physiochem. v.21 no.4 The Oxidation of Nitrogen in Combustion and Explosions Zeldovich, J.
  6. 가정용 난방연료 연소시 가스상 물질의 배출계수 추정에 관한 연구 김성미
  7. 수원지역에 적합한 분산 모델의 상대적 평가 및 배출계수에 관한 연구 박덕신
  8. 대형 연소시설의 NOx 배출계수 산정을 위한 공동조사 국립환경연구원