초록
This paper presents the automatic plumbness measuring system form improving the accuracy and working time for plumbness measuring of semi-umbrella type hydraulic turbine generator. It is general practice that rotating shaft should run within acceptable vibration limit. In order to obtain more accurate measuring data for single stage shaft on the semi-umbrella type, plumbness approach must be established carefully and accurately. Generally, present plumbness procedure is required several calculation algorithm, laser sensor and data acquisition devices. As a result of application to actual new system it is confirmed that working time could be saved over 80% and accurate measurement data could be acquired.