Bioequivalence Evaluation of Pylocin Tablet to Klaricid Tablet (Clarithyomycin, 250 mg)

클래리시드 정(클래리스로마이신 250 mg)에 대한 파이로신 정의 생물학적 동등성

  • Cho, Hea Young (College of Pharmacy and Research institute of Drug Development, Chonnam National University) ;
  • Kim, Soo Jin (College of Pharmacy and Research institute of Drug Development, Chonnam National University) ;
  • Sim, Young Sun (College of Pharmacy and Research institute of Drug Development, Chonnam National University) ;
  • Lim, Dong Koo (College of Pharmacy and Research institute of Drug Development, Chonnam National University) ;
  • Oh, In Joon (College of Pharmacy and Research institute of Drug Development, Chonnam National University) ;
  • Lee, Yong Bok (Medical School, Chonnam National University) ;
  • Moon, Jai Dong (Medical School, Chonnam National University)
  • 조혜영 (전남대학교 약학대학/약품개발연구소) ;
  • 김수진 (전남대학교 약학대학/약품개발연구소) ;
  • 심영순 (전남대학교 약학대학/약품개발연구소) ;
  • 임동구 (전남대학교 약학대학/약품개발연구소) ;
  • 오인준 (전남대학교 약학대학/약품개발연구소) ;
  • 이용복 (전남대학교 의과대학) ;
  • 문재동 (전남대학교 의과대학)
  • Published : 2000.06.01

Abstract

The bioequivalence of two clarithromycin tablets, the $Klaricid^{TM}$ (Ciba-Geigy Korea Ltd.) and the $Pylocin^{TM}$ (Kyungdong Pharmaceutical Co., Ltd.), was evaluated according to the Korean Guidelines for Bioequivalence Test (KGBT 1998). Sixteen healthy male volunteers ($20\sim26$ years old) were randomly divided into two groups and a randomized $2\times2$ cross-over study was employed. After one tablet containing 250 mg of clarithromycin was orally administered, blood sample was taken at predetermined time intervals, and the concentrations of clarithromycin in serum were determined using high-performance liquid chromatographic method with electrochemical detector. The pharmaco-kinetic parameters (area under the concentration-time curve: $AUC_t$, maximum concentration; $C_{max}$ and time to maximum concentration; $T_{max}$) were calculated and analysis of variance (ANOVA) was utilized for the statistical analysis of parameters. The results showed that the differences in $AUC_t,\;C_{max}\;and\;T_{max}$ between two tablets based on $Klaricid^{TM}$ tablet were $-0.22\%,\;-0.48\%\;and\;-1.63\%$, respectively. The powers $(1-\beta)\;for\;AUC_t,\;C_{max}\;and\;T_{max}\;were\;99.07\%,\;88.15\%\;and\;99.99\%$, respectively. Detectable differences $(\Delta)\;and\;90\%$ confidence intervals ($\alpha$=0.10) were all less than $\pm20\%$ All the parameters above met the criteria of KGBT 1998, indicating that $Pylocin^{TM}$ tablet is bioequivalent to $Klaricid^{TM}$ tablet.

Keywords