DOI QR코드

DOI QR Code

Failure Mode of the Positive Plate on Charging Voltage in Gel Type Valve Regulated Lead Acid Batteries

충전전압에 따른 겔형 VRLA전지 양극판의 파손방식

  • Published : 2000.05.01

Abstract

Cycle life test was carried out to evaluate the failure modes of the gel type nth batteries at $C_5$ currents and $100\%$ DOD. When the batteries were charged at constant voltage of 2.40 V and 2.50 Vi respectively, cycle lift was over 1,000 cycles. The batteries lost 426.4 g and 391.2 g of electrolyte far each case after the weight measurement. The battery charged at 2.50 V was shown to have a better cyclic performance than charged at 2.40 V, and the amounts of electrolyte loss was proportional to charge factor. After cycle test, the micro-structure of positive active material was completely changed and the corrosion layer of positive grid was about $50{\mu}m$. Failure mode of the positive plate of the gel type battery was a shedding of the positive active material, and the cause of discharge capacity decrease was found to be a electrolyte loss.

겔형 VRLA전지의 파손방식을 조사하기 위하여 $100\%$ 방전심도에서 5시간율 전류로 충방전 수명시험을 하였다. 정전압 충전방식을 사용하여 충전전압을 2.40V와 2.50V로 하였을 때 1,000회 이상의 수명을 나타내었으며, 전지의 무게변화를 측정한 결과 각각 426.4g과 391.2g의 전해액이 감소하였다 2.50V로 충전한 전지가 우수한 수명특성을 나타내었으며, 전해액 손실량이 충전계수와 비례하는 것을 알 수 있었다 1,000회의 충방전 수명시험을 한 전지의 양극기판에는 약 $50{\mu}m$의 부식층이 관찰되었고, 활성물질의 미세구조는 크게 변하였다. 양극판의 파손방식은 활물질 탈락이며, 전해액 손실이 방전용량 감소의 원인인 것을 알 수 있었다.

Keywords