Flow through turbomachinery has a very complex structure and Is Intrinsically unsteady. In addition, trend to highly loaded turbomachinery makes the flow extremely complex due to the interaction between rotor and stator. In this study, flows through UTRC LSRR turbine are numerically analyzed using 2 dimensional Navier-Stokes equations. The convective terms of the governing equations are discretized using the Van-Leer's FVS(Flux vector splitting) with an upwind TVD scheme. The conventional central differencing is used to discretize the diffusion terms on the finite volume. The accurate unsteady motion is achieved by using a 2nd order accurate, 3-point Euler implicit scheme. The quasi-conservative zonal scheme is used for calculating the flow variables on the zonal interface between the rotor and stator. The axial gap between stator and rotor has been configured in two variations, 15% and 65% of average chord length. The analysis program is validated using experimental results and the effect of axial gap is examined. The numerical analysis results are presented by time averaged pressure coefficient and pressure magnitude coefficient and compared with experimental results.