Abstract
We already presented new calculation method about the temperature distribution in hot water pipe flow of the unsteady condition. In this paper, we introduce consequence of the case study to confirm appropriation of the calculation method, and case study performs to establish actual hot water use supposed two model that is; the CWV(constant water volume) and VWV(variable water volume).
Keywords