Surface characteristics and biocompatibility of bioinert nitrides ion plated titanium implant

생불활성 질화물 이온도금된 티타늄 임프란트의 표면특성 및 생체적합성

  • Chang, Kap-Sung (Dept. of Periodontology College of Dentistry, Chosun University) ;
  • Kim, Heung-Joong (Dept. of Oral Anatomy College of Dentistry, Chosun University) ;
  • Park, Joo-Cheol (Dept. of Oral Histology College of Dentistry, Chosun University) ;
  • Kim, Byung-Ock (Dept. of Periodontology College of Dentistry, Chosun University) ;
  • Han, Kyung-Yoon (Dept. of Periodontology College of Dentistry, Chosun University)
  • 장갑성 (조선대학교 치과대학 치주과학교실) ;
  • 김흥중 (조선대학교 치과대학 구강해부학교실) ;
  • 박주철 (조선대학교 치과대학 구강조직학교실) ;
  • 김병옥 (조선대학교 치과대학 치주과학교실) ;
  • 한경윤 (조선대학교 치과대학 치주과학교실)
  • Published : 1999.03.30

Abstract

Even though titanium(Ti) and its alloys are the most used dental implant materials, there are some problems that Ti wears easily and interferes normal osteogenesis due to the metal ions. Ti coated with bioactive ceramics such as hydroxyapatite has also such problems as the exfoliation or resorption of the coated layer, Recent studies on implant materials have been proceeding to improve physical properties of the implant substrate and biocompatibility of the implant surfaces. The purpose of the present study was to examine the physical property and bone tissue compatibility of bioinert nitrides ion plated Ti, Button type specimens(14mm in diameter, 2.32rrun in height) for the abrasion test and cytotoxicity test and thread type implants(3.75mm in diameter, 6mm in length) for the animal experiments were made from Ti(grade 2) and 316LVM stainless steel. Ti specimens were ion plated with TiN, ZrN by the low temperature arc vapor deposition, and the depth profile of the TiN/Ti, ZrN/Ti ion plated surface was examined by Auger Electron Spectroscopy. Three kind of button type specimens .of TiN/Ti, ZrN/Ti and Ti were used for abrasion test, and HEPAlClC7 cells and CCD cells were cultivated for 4 days with the specimens for cytotoxicity test. Thread type implants of TiN/Ti, ZrN/Ti, Ti, 316LVM were implanted on the femur of 6 adult dogs weighing 10kg-13kg. Two dogs were sacrified for histological examination after 45 days and 90 days, and four dogs were sacrified for the removal torque test of the implant') after 90 days. The removal torque force was measured by Autograph (Shimadzu Co., AGS-1000D series, Japan). Abrasion resistance of TiN/Ti was the highest, and that of ZrN/Ti and Ti were followed. The bioinert nitride ion plated Ti had much better abrasion resistance, compared with Ti, In the cytotoxicity test, the number of both cells were increased in all specimens, and there were no significant difference in cytotoxic reaction among all groups (p>0.1), In histological examination, 316LVM showed the soft tissue engagement in interface between the implant and bone, but the other materials after 45 days noted immature new bone formation in the medullary portion along the implant surface, and those after 90 days showed implant support by new bone formation in both the cortical and the medullary portion, The removal torque force of Tilv/Ti showed significantly higher than that of Ti(p(O,05). The difference in removal torque force between TiN/Ti and ZrN/Ti was not significant(p>0.05), and that of 316LVM was lowest among all groups(p<0.05). These results suggest that bioinert nitrides ion plated Ti can resolve the existing problems of Ti and bioactive ceramics, and it may be clinically applicable to human.

Keywords