Quantitative Analysis of Trace pp'-DDE in Corn Oil by Isotope Dilution Mass Spectrometry : Uncertainty Evaluations

  • Published : 1999.08.20

Abstract

A current interest in chemistry concerns traceability of analytical measurements to the International System of Units (SI) and the proper estimation of their uncertainties in accordance with the internationally agreed guide provided by the International Organization for Standardization (ISO). Isotope dilution mass spectrometry (IDMS) is regarded as a primary method, which make the measurement results traceable to SI units without significant empirical correction factors. Our laboratory, as the national standards institute of Korea, participated in an intercomparison of environmental analysis, pp'-DDE in corn oil, which was organized by the CCQM under supervision of the CIPM to test feasibility of IDMS as a primary method for the trace analysis of organic compounds. In this report, we provide basic equations used for the calculation of the concentration of the analyte in a sample and a precise description of the processes for the evaluation of the uncertainties of the measurement results. Also, we report the experimental conditions adopted to improve the accuracy of the IDMS measurement. The principles contained in ??Guide to the Expression of Uncertainty in Measurement'' provided by ISO are followed for the uncertainty evaluation.

Keywords

References

  1. Accreditation and Quality Assurance De Bivere, P.;Gnzler, H.(Ed.)
  2. Int. J. Environ. Anal. Chem. v.52 De Bivere, P.
  3. Metrologia v.34 Richter, W.;Dube, G.
  4. Metrologia v.34 King, B.
  5. Metrologia v.34 De Bivere, P.;Taylor, P. D. P.
  6. Guide to the Expression of Uncertainty in Measurement International Organization for Standardization (ISO)
  7. Quantifying Uncertainty in Analytical Measurement Eurachem
  8. Metrologia v.34 Quinn, T. J.
  9. Metrologia v.34 Dube, G.;Henrion, A.;Richter, W.
  10. Anal. Proceedings v.30 De Bivere, P.
  11. Mass Spectrom. Rev. v.11 Heumann, K. G.
  12. Mass Spectrom. Rev. v.11 De Leenheer, A. P.;Thienpont, L. M.
  13. Int. J. Mass Spectrom. Ion Processes v.118;119 De Leenheer, A. P.;Thienpont, L. M.
  14. J. Clin. Chem. Clin. Biochem. v.23 Lawson, A. M.;Gaskell S. J.;Hjelm, M.
  15. Anal. Chem. v.61 Ellerbe, P.;Meiselman, S.;Sniegoski, L. T.;Welch, M. J.;White, V. E.
  16. Clin. Chem. v.65 Bowers, Jr., G. N.;Fassett, J. D.;White, V. E.
  17. Anal. Chem. v.60 Takatsu, A.;Nishi, S.
  18. Biomed. Mass Spectrom. v.12 Covey, T.;Maylin, G.;Henion, J.
  19. Mass Spectrometry in Biomedical Research Harvey, D.;Gaskell, S.(Ed.)
  20. Chemosphere v.17 de Boer, J.
  21. J. Assoc. Off. Anal. Chem. v.67 Young, S.;Clower, C.;Roach, J. A. G.
  22. J. Assoc. Off. Anal. Chem. v.59 Johnson, L. D.;Waltz, R. H.;Ussary, J. P.;Kaiser, F. E.
  23. Clin. Chem. v.26;27 Cohen, A.;Hertz, H. S.;Mandel, J.;Paule, R. C.;Schaffer, R.;Sniegoski, L. T.;Sun, T.;Welch, M. J.;White, V. E.
  24. Instructions of the JMS-700 Mstation Jeol
  25. Operating Instructions for Mettler Toledo AT Balances Mettler Toledo