A Study on Safety Blasting Design with Blast Vibration Analysis Urban Area

도심지 미진동 제어 발파에서 진동분석을 통한 안전발파설계에 관한 연구

  • 안명석 (안명석기술사무소) ;
  • 박종남 (동아대학교 공과대학 자원공학과) ;
  • 배상근 (경북대학교 공과대학 토목공학과)
  • Published : 1999.06.01

Abstract

A study was made on the design of the prediction model concerning blasting vibration in a constraction site, Namgu, Daegu City. The geology in this area consists of hornfels of shale and mud underlain by quartize, of which the main strike of the geological structure is NW direction. Measurements were carried out on the top of the wall concrete water storage tank, which is burried in the ground earth. The attenuation due to the vertical wall of the concrete structure may be experted because of spherical divergency at the bottom corner of the wall by the Huygens principle. For design of blasting prediction model, thus among scaled distance(SD) may be preferable to use in the regression model, since they represents most likely the average ground condition. Judging from the regression results, the cube root method may be more suitable for this area. The SD values for the maximum allowable vibration velocity of 0.5 cm/s, in this area are 22.5, 28.0 and 30.6 for the significance level of 50%, 95% and 99%, respectively.

도심지 건물 부지조성공사를 위한 발파예측식에 대한 사례연구를 수행하였다. 대상지역은 대구광역시 남구 대명동 산 201-4 일대로써 지질은 상부에 세일 이암이 호온펠스화한 치밀한 암석과 그 하부는 규장암을 기반으로 하고 있으며 지질구조는 주요 주향방향은 NW방향이고 부축방향은 EW이다. 진동 측정은 지상고 6m 높이의 상수용 수조콘크리트 구조물 상부에서 측정되었으며, 이때 구조물에 의한 파의 감쇄현상이 상당히 큼으로서 경제적인 발파설계를 위하여는 환산거리가 큰 직선상의 속도분석에 의한 설계가 유효할 것이며, 경제적인 발파설계를 위하여는 환산가리가 큰 직선상에 의한 설계가 유효할 것이며, 또한 거리계수를 고려하면 삼승근의 경우가 자승근의 경우보다 더 낮다고 생각되며 이때 안전발파를 위나 최대허용속도 0.5cm/s에 대한 50%, 95%, 99%의 유의수준에서의 환산거리는 각각 22.5, 28.0 및 30.6이었다.