Local Heat Transfer Coefficients for Reflux Condensation Experiment in a Vertical Tube in the Presence of Noncondensible Gas

  • Published : 1999.10.01

Abstract

The local heat transfer coefficient is experimentally investigated for the reflux condensation in a countercurrent flow between the steam-air mixture and the condensate, A single vertical tube has a geometry which is a length of 2.4m, inner diameter of 16.56mm and outer diameter of 19.05mm and is made of stainless steel. Air is used as a noncondensible gas. The secondary side has a shape of annulus around vertical tube and the lost heat by primary condensation is transferred to the coolant water. The local temperatures are measured at 11 locations in the vertical direction and each location has 3 measurement points in the radial direction, which are installed at the tube center, at the outer wall and at the coolant side. In three different pressures, the 27 sets of data are obtained in the range of inlet steam flow rate 1.348∼3.282kg/hr, of inlet air mass fraction 11.8∼55.0%. The investigation of the flooding is preceded to find the upper limit of the reflux condensation. Onset of flooding is lower than that of Wallis' correlation. The local heat transfer coefficient increases as the increase of inlet steam flow rate and decreases as the increase of inlet air mass fraction. As an increase of the system pressure, the active condensing region is contracted and the heat transfer capability in this region is magnified. The empirical correlation is developed by 165 data of the local heat transfer. As a result, the Jacob number and film Reynolds number are dominant parameters to govern the local heat transfer coefficient. The rms error is 17.7% between the results by the experiment and by the correlation.

Keywords

References

  1. M.S. Thesis, Dept. of Nuclear Engineering, Korea Advanced Institute of Science and Technology An Experimental Investigation of Condensation Phenomena In A Vertical U-tube With and Without Noncondensible Gas J.W.Park
  2. ASME Winter Annual Meeting Reflux Condensation and Transition to Natural Circulation in a Vertical U-tube S.Banerjee;J.S.Chang;R.Girard;V.S.Krishnan
  3. ANS Trans. v.43 Flow Regimes and Removal Mechanisms in a Single Inverted U-tube Steam Condenser Q.Nguyen;S.Banerjee
  4. Proc. 7th Int. Heat Transfer Conf. The Distribution of Gas in a U-tube Heat Exchanger and its Influence on the Condensation Process D.Hein(et al.)
  5. EPRI/NP-2648 Reflux Condensation and Operation Limits of Countercurrent Vapor-Liquid Flows in a Closed Tube C.L.Tien;T.Fukano;K.Hijikata;S.J.Chen
  6. 3rd Multiphase Flow and Heat Transfer Symposium Workshop The Role of Flooding Phenomena in Reflux Condensation in a Vertical Inverted U-tube P.T.Wan;R.Girard;J.S.Chang
  7. 4th Canadian Nuclear Soc. Conf. Heat Removal Capability of Steam Generators under Reflux Cooling Modes in a CANDU-PHT System J.S.Chang;R.Girard;S.Revankar;P.T.Wan
  8. Nuclear Technology v.102 Local Heat Transfer Coefficients for Force-Convection Condensation of Steam in a Vertical Tube in the Presence of a Noncondensible Gas M.Siddique;M.W.Golay;M.S.Kazimi
  9. One-dimensional Two-phase Flow G.B.Wallis
  10. Nuclear Technology v.127 no.2 A Condensation Experiment in the Presence of Noncondensables in a Vertical Tube of PCCS and Its Assessment with RELAP5/MOD3.2 Hyun Sik Park;Hee Cheon NO