Abstract
In this paper, the seismic analysis model for seismically isolated KALIMER reactor structures is developed and the modal analysis and the seismic time history analysis are carried out for seismic isolation and non-isolation cases. To check the seismic stress limit according to the ASME Code, the equivalent seismic stress analyses are preformed using the 3-D finite element model. From the seismic stress analysis, the seismic margins are calculated for structural members. The limit of seismic load is defined to show that the maximum input acceleration ensures the structural safety for seismic load. In comparison of seismic responses between seismic isolation and non-isolation cases, the seismic isolation design gives significantly reduced acceleration responses and relative displacements between structures. The seismic margin of KALIMER reactor structure is high enough to produce the limit seismic load 0.8g.
본 연구에서는 현재 국내에서 면진설계를 적용하여 개발중인 KALIMER(Korea Advanced Llquid Metal Reactor) 액체금속로에 대한 내진설계 및 지진해석을 위하여 핵심구조물인 원자로구조물에 대한 단순 지진해석모델을 개발하였다 이를 이용하여 면진설계의 경우와 비면진 설계의 경우에 대한 동특성분석과 시간이력 지진해석을 수행하여 비교평가하였다. 또한 ASME 설계코드에 따른 응력한계요건을 검토하기 위하여 등가 지진응력해석을 수행하고 이로부터 내진여유도를 계산하였다 지진안전성에 대한 하나의 지표로서 원자로 구조물이 견딜수 있는 최대지진하중을 결정하기 위한 한계지진하중(Limit seismic load)을 저의하였다 지진해석결과 면진된 KALIMER 원자로구조믈은 비면진된 경우에 비하여 가속도응답과 구조물간의 상대변위응답이 현저히 감소하였고 충분한 내진여유도로 인하여 한계지진하중이 0.8g로 나타났다.