Abstract
In this paper, a method of canceling and suppressing differential-mode crosstalk-noise signals caused by non-uniform coupling between two transmission lines in UTP(Unshielded Twisted Paris) modular jacks is discussed. Differential-mode crosstalk-noise signals in balanced transmission lines in UTP modular jacks were suppressed by inserting auxiliary capacitance between balanced transmission line pairs which are located closely enough to be effectively coupled each other. To verify the effectiveness of the inserted capacitances, precisely calculated auxiliary capacitances were applied to 10 pin modular jacks which are used in local area networks at 100 Mb/s with unshielded twisted pair-cables. The NEXT(Near-End Crosstalk) losses were measured to prove its applicability.
본 논문에서는 100 Mb/s Unshielded Twisted Pairs (UTP) 케이블 Modular Jack의 평형 통신 시스템(Balanced Communication System)에서 시스템의 성능에 영향을 주지 않으변서, UTP 케이블의 꼬임이 풀림 으로 인해 서로 근접하게 배치된 평형통신 선로(Balanced Communication Lines)간에 존재하는 불균일한 결 합으로 인한 차등 누화 선호(Differen tial- Mode Crosstalk Signal)를 효과적으로 제거하거나 억제시킬 수 있는 접근 방법에 대하여 논하고 있으며, 실제 UTP 케이블의 Modular Jack에 이를 적용시켜 이에 대한 큰단누화 (Near-End Crosstalk (Next)를 측정함으로써 그 타당성을 입증하였다.