Measurement Technique of Required Spark Voltage Using Primary Ignition Voltage and Misfire Application in a SI Engine

SI엔진에서 점화 1차 전압을 이용한 방전요구전압의 측정기법과 실화적용에 관한 연구

  • 박경석 (금오공과대학교 기계공학부)
  • Published : 1999.12.01

Abstract

In this study , a simple method has been developed to detect the required spark voltage by using the primary spark voltage instead of the secondary spark voltage. Through engine motoring experiments, this method testified to be quite satisfactory. Though the required spark voltage is affected by many in-cylinder conditions, temperature is one of the most important factors. The temperature increases significantly by combustion and the required spark voltage also changes by the temperature during the expansion stroke. On the basis of this fact, misfire can be monitored by comparing the required spark voltage between compression stroke and expansion stroke. So, in this study, two step ignition method is introduced to monitor combustion at expansion stroke. The test result shows that this method can be used to detect complex misfire pattern.

Keywords

References

  1. SAE Paper 930399 Misfire Detection by Evaluating Crankshaft Speed-A Means to Comply with OBD Ⅱ Martin Klenk;Winfried Moser
  2. 서울대학교 공학박사 학위 논문 크래크축 각속도의 변동을 이용한 실린더내 압력 변화와 토크의 추정 임병진
  3. SAE 960622 Misfire detection in a high-performance engine by the principal component analysis approach Azzoni, Piero Mario ENEA Moro;Porceddu-Cilione;Carlo Maria ENEA Rizzoni
  4. SAE 980515 Misfire detection using a dynamic neural network with output feedback Wu, Zhijian James Chrysler Corp. Lee
  5. SAE 96C003 Engine Control by Ion Density Analysis S. Miyata;K. Nishio;N. Kondo
  6. SAE 950004 Ion-Gap Sense in Misfire Detection, Knock and Engine Control J. Auzins;H. Johansson;J. Nytomt
  7. Internal Combustion Engine Fundamentals J. B. Heywood
  8. 자동차기술핸드북(2)설계편 한국자동차공학회