Abstract
The ozone concentrations measured at the National Air Monitoring Stations between 1990 and 1995 were reviewed to detect any anomalies in the measurements. By screening the cases, in which variation of the ozone concentration from the previous measured value is greater than 75ppb, 125 station-days were identified as the test cases for the anomaly test. Historical and parallel consistencies of the measured concentrations were examined by plotting data for each test case. The detected anomalies can be classified into four categories; single outliers, anomalous variations during the startup period, baseline rises, and fluctuations in th diurnal variations. Anomalies were detected in as many as 80 cases among 125 test cases. Because of these anomalies, the number of hours exceeding 100ppb in the areas other than the Greater Seoul Area(GSA) could decrease from 157 to 107. Further studies for developing the methodology for eliminating the abnormal monitoring data are warranted for the data from the National Air Monitoring Stations are official to the both inside and outside of the country.