Performance Prediction of Centrifugal Pumps using a Two Zone Model

두영역모델을 사용한 원심펌프의 성능예측

  • 최영석 (한국생산기술연구원 냉동공조연구팀) ;
  • 심재혁 (한국생산기술연구원 냉동공조연구팀) ;
  • 강신형 (서울대학교 기계공학과)
  • Published : 1999.03.01

Abstract

In this study, the performance prediction programs for centrifugal pumps are developed. To estimate the losses in the centrifugal pump impellers, a two-zone model and TEIS(two elements in series) model are applied to the program. The basic concept of a two zone model considers the primary zone that is an isentropic core flow and the secondary zone that has a non-isentropic region at the impeller exit. The flow goes through two different zones and is mixed out at the impeller exit and the mixing process occurs with an increase in entropy, a decrease in total pressure. The level of the core flow diffusion in an impeller was calculated using TEIS(two elements in series) model. The effects of various parameters which are used in this program on the prediction of head and efficiency are discussed. The correlation curves used to select the effectiveness of the primitive TEIS model were suggested according to the specific speed of the centrifugal pumps.

Keywords