The Comparison of DVH between Multiple arc FSRT and Conformal FSRT
Multiple arc FSRT와 Conformal FSRT의 DVH 비교
- Kim Ki-Hwan (Department of Therapeutic Radiology, Chungnam National University Hospital) ;
- Kim Jun-Sang (Department of Therapeutic Radiology, Chungnam National University Hospital) ;
- Jang JiYoung (Department of Therapeutic Radiology, Chungnam National University Hospital) ;
- Kim Jae-Sung (Department of Therapeutic Radiology, Chungnam National University Hospital) ;
- Kim Seong-Ho (Department of Neurosurgery, Chungnam National University Hospital) ;
- Song Chang-Joon (Department of Diagnostic Radiology, Chungnam National University Hospital) ;
- Park Min-Kyu (Department of Physics, College of Natural Science, Chungbuk National University) ;
- Cho Moon-June (Department of Therapeutic Radiology, Chungnam National University Hospital)
- 김기환 (충남대학교 의과대학 치료방사선과) ;
- 김준상 (충남대학교 의과대학 치료방사선과) ;
- 장지영 (충남대학교 의과대학 치료방사선과) ;
- 김재성 (충남대학교 의과대학 치료방사선과) ;
- 김성호 (충남대학교 의과대학 신경외과) ;
- 송창준 (충남대학교 의과대학 진단방사선과) ;
- 박민규 (충북대학교 자연과학대학 물리학과) ;
- 존문준 (충남대학교 의과대학 진단방사선과)
- Published : 1999.09.01
Abstract
Purpose : In FSRT (Fractionated stereotactic radiotherapy) planning, we studied the usefulness between multiple arc FSRT and conformal FSRT by comparing tumor shape and DVH (dose volume histogram). Materials and Methods In Chungnam Univ. hospital, we had treated the sixteen patients with FSRT from Aug. 1997 to Dec. 1998. In choosing multiple arc FSRT or conformal FSRT, we had considered If (irregular factor) after calculating tumor volume and surface area. We had considered multiple arc FSRT if tumor shape was similar to sphere or the value of If was less than 1.25, conformal FSRT if tumor shape was very irregular or If was more than 1.3. For evaluation of treatment planning, we had considered the appropriate DVH for tumor volume and for critical organs. Results : The errors between reference point and the coordinates point on AP, Lat radiography were less than 1 mm before treatment. We had planned
목적 : Multiple arc FSRT (fractionated stereotactic radiotherapy)와 conformal FSRT의 치료계획에 있어서 종양의 모양과 DVH (dose volume histogram)를 비교하여 두 기법간의 유용성에 대하여 논하고자 한다. 대상 및 방법 : 16명의 뇌종양 환자들을 대상으로 1997년 8월부터 1998년 12월까지 충남대학교병원 치료방사선과에서 112회의 FSRT를 실시하였다. 치료 전 모의치료에서 얻은 AP(Anterior-posterior), Lateral 필름상의 금속표지자의 좌표값을 ISOLOC프로그램에 입력하여 얻은 기준점과의 오차를 확인한 후 치료계획을 하였다. 치료계획은 종양용적과 종양표면적를 계산한 후 if (Irregular factor)를 고려하여 multiple arc FSRT 혹은 conformal FSRT를 선택하였다. Multiple arc FSRT는 종양의 IF값이 1-1.2인 경우에 고려하였고, conformal FSRT는 IF값이 1.3 이상인 경우에 고려한 후 종양용적에 대하여 처방선량 이상의 선량에 대한 DVH곡선에 의한 면적이 최소이면서 처방선량 이하의 선량에 대한 DVH곡선에 의한 면적이 최대가 되도록 하는 치료계획을 선택하여 평가하였다. 결과 : 치료전 모의치료에서 시행한 금속표지자의 좌표값을 ISOLOC프로그램에 입력하여 얻은 기준점과의 오차는 1 mm 이내였다. Huitlple arc FSRT는 누적DVH상에서 처방선량의 90, 91, 92,