DOI QR코드

DOI QR Code

The use of small scale model testing to compare connection methods of steel purlins

  • Urquhart, Stephen M. (The University of Western Australia) ;
  • Kavanagh, Kenneth T. (The University of Western Australia)
  • Published : 1998.07.25

Abstract

Testing of steel roof purlins is usually performed on full scale models in large vacuum test rigs. To undertake a comparison between web cleat connected purlins and flange bolted purlins a series of tests were performed on a 1:4 small scale model vacuum test rig. Various modelling issues need to be addressed to ensure reasonable comparison with actual constructed roof framing methods but still be suitable for an economical comparison between the connection methods. Model test results were supported by, and found to be in reasonable agreement with, deflection predictions from computer models based on finite element methods. This paper discusses the testing methods adopted and the value of small scale model testing programs as a means of obtaining comparisons between framing options.

Keywords

References

  1. Bradford, M.A. (1990), "Local buckling of steel purlins and girts", Australian Civil Engineering Transactions, The Inst. Eng. Aust., CE32(1), 29-35.
  2. Chajes, A. (1974), Principles of Structural Stability Theory, Prentice Hall Inc., Englewood Cliffs, N.J.
  3. Hancock, G.J. (1994), Design of Cold-Formed Steel Structures, 2nd Ed, Australian Institute of Steel Construction, Sydney.
  4. Hancock, G.J., Celeban, M. and Healy, C. (1993), "Behaviour of purlins with screw fastened sheeting under wind uplift and downwards loading", Australian Civil Engineering Transactions, The Inst. Eng. Aust., CE35(3), 221-233.
  5. Kavanagh, K.T. (1996), Computer programs, AISC1, AISC2, AISC7, AISC8, AISC9 and AISC10, and associated notes, University of Western Australia, (unpublished).
  6. Lysaght Building Industries (1993), Zeda & Cees Purlin & Girt System - Product Information, Ref: AP6320-10/93, John Lysaght(Australia)Ltd, NSW.
  7. Lysaght Building Industries (1993), Zeda & Cees Purlin & Girt System - Safe Load Tables & Design Data, Ref: AP6534-10/93, John Lysaght(Australia)Ltd, NSW.
  8. Standards Australia (1981), SAA Steel Structures Code, AS1250-1975, SAA, Sydney.
  9. Standards Australia (1984), Steel Sheet and Strip - Hot-Dipped Zinc-Coated of Aluminium/Zinc-Coated, AS 1397-1984, SAA, Sydney.
  10. Standards Australia (1998), Cold-Formed Steel Structures Cods, AS 1538-1988, SAA, Sydney.
  11. Toma, T. and Wittemann, K. (1994), "Design of cold-formed purlins and rails restrained by sheeting", J. Constructional Steel Research, 31, 149-168. https://doi.org/10.1016/0143-974X(94)90008-6
  12. Urguhart, S.M. (1996), The Behaviour of Purlins Without Cleats, Master of Engineering Science dissertation, The University of Western Australia, .
  13. Zetlin, L. and Winter, G. (1955), "Unsymmetrical bending of beams with and without lateral bracing", Proceedings of ASCE, 81(Aug), 774-1 to 774-20.