Abstract
In this study, the extraction of Co(Ⅱ) and Cu(Ⅱ) into chloroform solution of dithizone, distribution ratios, extractabilities and extraction rate constants of the metal complexes were compared in each case with which thiocyanate ion was or not used as the auxiliary ligand. The use of the thiocyanate ion increased threefold the distribution ratio for Co(Ⅱ) complex in a basic solution and twofold for Cu(Ⅱ) complex in a wide pH range. And the extractability was also augmented from about 90 to 99 for Co(Ⅱ) and from 95 to 99 for Cu(Ⅱ) in a given period. The extraction rate constants were $k_1\;:\;1.2{\times}10^5$, $k_2\;:\;1.34{\times}10^{17}\; mol^{-1}dm^3s^{-1}$ in case of Co(Ⅱ) and$k_1\;:\;1.1{\times}10^8$, $k_2\;:\;2.83{\times}10^{10}\; mol^{-1}dm^3s^{-1}$ in case of Cu(Ⅱ) on the extraction of dithizonate complexes into chloroform solution.
Co(Ⅱ)와 Cu(Ⅱ)의 금속이온을 디티존의 클로로포름용액으로 추출할 때, 보조 리간드로 티오시안산이온을 사용하여 금속착물의 분포비, 추출률 및 추출속도상수를 구하여 보조 리간드를 사용하지 않았을 경우와 비교하였다. 착물의 분포비는 보조 리간드가 없을 때보 다 보조 리간드가 있을 때, Co(Ⅱ)는 염기성에서 3배 정도, Cu(Ⅱ)는 넓은 pH범위에서 2배 정도 더 크게 나타났고, 추출률은 보조 리간드가 존재하면 Co(Ⅱ)는 90에서 99%로, Cu(Ⅱ)는 95에서 99%로 증가하였다. 그리고 추출속도상수 $k_1\;은\;Co(Ⅱ):1.2{\times}10^5, k_2: 1.34{\times}10^{17} mol^{-1}dm^3s^{-1}$이였으며 Cu(Ⅱ)는$k_1\;과\;k_2$가 각각$1.1{\times}10^8과\;2.83{\times}10^{10} mol^{-1}dm^3s{-1}이였다.