Anodic Stripping Voltammetric Determination of Cadmium(Ⅱ) Using Alga-Modified Carbon Paste Electrodes

Alga변성전극을 이용한 Cadmium(Ⅱ)의 양극벗김 전압-전류법적 정량

  • Bae, Zun Ung (Department of Chemistry, Kyungpook National University) ;
  • Choi, Jung Eun (Department of Chemistry, Kyungpook National University) ;
  • Chang, Hye Young (Department of Chemistry, Kyungpook National University)
  • 배준웅 (경북대학교 자연과학대학 화학과) ;
  • 최정은 (경북대학교 자연과학대학 화학과) ;
  • 장혜영 (경북대학교 자연과학대학 화학과)
  • Published : 19980200

Abstract

Microorganisms such as alga are able to uptake toxic and heavy metal ions. After Cd(Ⅱ) was preconcentrated on the carbon paste electrode constructed by incorporating alga (Anabaena), it was determined with differential pulse anodic stripping voltammetry. A well-defined oxidation peak of Cd(Ⅱ) was obtained at - 0.75 V vs. SCE. We investigated the optimum conditions using the peak, which are the effect of the amount of alga, pH, ionic strength, temperature, and preconcentration time on the preconcentration of Cd(Ⅱ) and that of the reduction time and potential on the reduction of Cd(Ⅱ) preconcentrated. Calibration curve for the determination of Cd(Ⅱ) was linear over the range of $1.0{\times}10^6\;M\;to\;8.0{\times}10^6$\;M (R=0.9978) and the detection limit was $5.0{\times}10^{-7}$\;M. The relative standard deviation was 3.1% (n=6) for $7.0{\times}10^{-6}\;M Cd(Ⅱ). In regeneration of the electrode surface with 0.1 M HCl, the response was reproducible continuously by 10 times.

Alga와 같은 미생물은 중금속을 흡수한다. Alga(Anabaena)로 변성시킨 탄소반죽전극으로 Cd(Ⅱ)이온을 사전농축시켜서 Cd(Ⅱ)을 양극벗김 펄스차이 전압-전류법으로 정량하였다. Cd(Ⅱ)의 산화봉우리는 -0.75V vs. SCE.에서 나타났으며, 이 봉우리를 이용하여 Cd(Ⅱ) 정량의 최적조건을 조사하였다. 변성전극의 제작에 미치는 alga양의 영향과 Cd(Ⅱ)의 사전농축에 미치는 pH와 이온세기, 온도 및 사전농축시간에 대한 영향을 조사하였으며. 전극표면에 사전 농축시킨 Cd(Ⅱ)이온을 전해환원시키는 시간과 전위의 영향도 조사하였다. Cd(Ⅱ)을 정량하기 위한 검정선은 $1.0{\times}10^6\;M ~ 8.0{\times}10^6\;M$범위에서 직선성(상관계수는0.9978)이 성립하였고 검출한계는 $5.0{\times}10^{-7}\;M$이었다. $7.0{\times}10^{-6}\;M$ Cd(Ⅱ)용액에서 얻은 상대표준편차는 3.1%(n=6)이었다. Alga변성전극의 사용횟수는 0.1M HCl 용액으로 전극표면을 재생시킬 때에 10회까지 연속측정이 가능하였다.

Keywords

References

  1. J. Am. Chem. Soc. v.103 Albert, W. J.;Eddow es, M. J.
  2. Anal. Chem. v.54 Stutts, K. J.;Wightmann, R. M.
  3. J. Electronal. Chem. v.85 Nagy, G.;Gerhardt, G. A.;Oke, A. K.;Rice, M. E.;Adams, R. N.
  4. J. Electrochem. Soc. v.131 Bull, R. A.;Fan, F. R.;Bard, A. J.
  5. Anal. Chem. v.58 Baldwin, R. P.;Christensen, J. K.;Kryger, L.
  6. Anal. Chim. Acta. v.232 Gao, Z.;Li, P.;Dong, S.;Zhao, Z.
  7. Anal. Chem. v.321 Kalcher, K.;Fresenius, Z.
  8. Anal. Chem. v.61 Liu, K. E.;Abruna, H. D.
  9. Anal. Lett. v.11 Cheek, G. T.;Nelson, R. P.
  10. Anal. Chem. v.58 O'Riordan, D. M. T.;Wallace, G. G.
  11. Anal. Lett. v.20 McCraken, L. L.;Wier, L. M.;Abruna, H. D.
  12. Bull. Korean Chem. Soc. v.17 Bae, Z. U.;Park, Y. C.;Lee, S. H.;Jeon, W. S.;Chang, H. Y.
  13. Anal. Chem. Acta. v.158 Wang, J.;Greene, B.;Morgan, C.
  14. Analyst. v.114 Hemandez, L.;Melguizo, J. M.;Blanco, M. H.;Hermandez, P.
  15. Anal. Chem. v.60 Gardea-Torresdey, J.;Darnall, D.;Wang, J.
  16. Anal. Chim. Acta. v.273 Ramos, J. A.;Bermejo E.;Zapardiel, A.;Perez, J. A.;Hern ndez, L.
  17. Biotechnol. Bioeng v.24 Khummongkol, D.;Canterford, C. S.;Fryer, C.
  18. J. Electroanal. Chem. v.252 Gardea-Torresdey, J.;Darnall, D.;Wang, J.
  19. Anal. Chem. v.1 Drake, L. R.;Rayson, G. D.
  20. Biotechnol. Bioeng. v.24 Tsezos, M.;Volesky, B.
  21. J. Environ. Eng. v.119 Nagendra, C. R.;Lyengar, L.;Benkobachar, C.
  22. Minerals Environ v.2 Jennett, J. C.;Hassett, J. M.;Smith, J. E.
  23. J. Environ. Sci. Technol. v.24 Harris, P. O.;Ramelow, G.
  24. J. Appl. Phycol. v.5 Fehrmann, C.;Pohl, P.
  25. Trace Meetal Removal from Aqueous Solution Darnall, D. W.;Green, B.;Hosea, M.;McPherson, R. A.;Henzl, M.;Alexander, M. D.;Thomson, R.(Ed.)