Abstract
The use of computers as part of nuclear safety systems elicits additional requirements-software verification and validation (v/v), hardware qualification-not specifically addressed in general industry fields. The computer used in nuclear power plants is a system that includes computer hardware, software, firmware, and interfaces. To develop the computer systems graded with nuclear safety class, the developing environments have to be required in advance and the developed software have to be verified and validated in accordance with nuclear code and standards. With this requirements, the test facility for Inadequate Core Cooling Monitoring System (ICCMS) as one of safety systems in the nuclear power plants was developed. The test facility consists of three(3) parts such as Input/Output (I/O) simulator, Plant Data Acqusition System (PDAS) cabinets and supervisory computer. The performance of the system was validated by manual test procedure.
원자력 안전계통의 일부분인 컴퓨터의 사용은 일반 산업분야에서 명시되지 않은 부가적인 요건 즉 소프트웨어의 확인 및 검증, 하드웨어의 품질요건이 요구된다. 원자력 발전소에서 사용되는 컴퓨터는 컴퓨터 하드웨어, 소프트웨어, 펌웨어 및 연계장치를 포함하는 시스템이다. 원자력 안전등급을 갖는 컴퓨터 시스템을 개발하기 위해서는 우선적으로 개발환경이 요구되고 개발된 소프트웨어는 원자력 코드 및 표준에 따라 확인 및 검증되어야 한다. 이러한 요건 때문에 원자력 발전소 안전계통의 하나인 부적절노심감시계통에 대한 시험설비가 개발되었다. 시험설비는 입출력 모의설비, 자료수집계통 케비넷 및 감시컴퓨터의 3부분으로 구성된다. 이 시스템의 성능을 수동시험절차에 따라 검증되었다.