Abstract
It is very important to test linear cycle positioning accuracy of NC lathes as it affect all other machines machined by them in industries. For example, if the linear positioning accuracy of x or z-axis directions is bad, the size of works will be wrong and the change-ability will be bad in the assembly of machine parts. In this paper , measuring systems are organized to measure linear displacement of ATC(Automatic tool changer) of NC lathe using laser interferometer, magnescale and tick pulses coming out from computer in order to get data at constant time intervals from the sensors, And each set of data gotten from test is expressed to a plots by computer treatment and the results of linear positioning error motion is estimated to numerics by statistical treatments.