Abstract
A numerical study has been peformed to investigate the flow and mixing characteristics of a chemical injection tank in the chemical and volume control system (CVCS) of Yonggwang 5&6 (YGN 5&6). This study was undertaken to provide a basis for modification of the previous design (YGN 3&4) which gave a lot of difficulties in installation and operation of the chemical injection system during the start-up test because it needs a special reciprocating pump with a high actual head. For the tank of length-to-diameter ratios (L/D) of 1,2 and 3, each with and without a baffle inside, calculation results were obtained by solving the unsteady laminar two-dimensional elliptic forms of governing equations for the mass, momentum and species concentration. Finite-difference method was used to obtain discretized equations, and the SIMPLER solution algorithm, which was developed based on the staggered grid control volume, was employed for the calculation procedure. Results showed that the baffle is very effective in enhancing the mixing in the tank and that a baffle should be installed near the tank entrance in order to 110 chemicals into the reactor coolant system (RCS) within the operating time required.