연속식 PCR과 BCR에서 pH 변화에 따른 페놀 폐수의 오존처리특성에 관한 연구
The Characteristics of the Ozonation of phenol wastewater by the variation of pH using the continuous PCR and BCR
초록
This study was performed to estimate the ozonation characteristics of phenol wastewater with increasing pH in the continuous packed column reactor (PCR) and the bubble column reactor (BCR). Among various influencing factors that affect phenol on decomposition through the ozonation, pH was chosen as reaction parameter. Upon increasing pH from 3 to 9, the phenol removal efficiency in PCR was improved approximately by 17% while in BCR approximately by 19.2%. The improvements in the phenol removal efficiency by increasing pH caused the enhancements in ozone utilization efficiency reaching almost 100% in PCR at pH 9. In conclusions, ozone has latent power for phenol wastewater treatment, and the performance of PCR was superior to that of BCR in the aspects of phenol removal and ozone utilization efficiency.